Evidence map›Paper›PMID 35706507›Full record

ArticleFrontiers in bioengineering and biotechnology2022

Improving the Stability of a Hemipelvic Prosthesis Based on Bone Mineral Density Screw Channel and Prosthesis Optimization Design.

Rongqi Zhou, Haowen Xue, Jincheng Wang, Xiaonan Wang, Yanbing Wang, Aobo Zhang, Jiaxin Zhang, Qing Han, Xin Zhao

Open access · goldAbstract read
In one paragraph

Article in Frontiers in bioengineering and biotechnology, 2022. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 5 papers.

0numbers the graph read from it
0cells of the map it votes in
5citing papers in PubMed
1.5field-weighted citation impact, top 18% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

5 citing papers in PubMed, 7 citations in OpenAlex.

  1. Article
  2. Article
  3. Article
  4. Article
  5. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

9 authors at 1 institution in 1 country.

Rongqi ZhouDepartment of Orthopedics, The Second Hospital of Jilin University, Changchun, China.
Haowen XueDepartment of Orthopedics, The Second Hospital of Jilin University, Changchun, China.
Jincheng WangDepartment of Orthopedics, The Second Hospital of Jilin University, Changchun, China.
Xiaonan WangDepartment of Orthopedics, The Second Hospital of Jilin University, Changchun, China.
Yanbing WangDepartment of Orthopedics, The Second Hospital of Jilin University, Changchun, China.
Aobo ZhangDepartment of Orthopedics, The Second Hospital of Jilin University, Changchun, China.
Jiaxin ZhangDepartment of Orthopedics, The Second Hospital of Jilin University, Changchun, China.
Qing HanDepartment of Orthopedics, The Second Hospital of Jilin University, Changchun, China.
Xin ZhaoDepartment of Orthopedics, The Second Hospital of Jilin University, Changchun, China.
Second Affiliated Hospital of Jilin University · CN

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

In pelvic reconstruction surgery, the hemipelvic prosthesis can cause significant changes in stress distribution due to its high stiffness, and its solid structure is not suitable for osseointegration. The purpose of this study was to identify a novel bone mineral density screw channel and design the structure of the prosthesis so as to improve the distribution of stress, promote bone growth, and enhance the biomechanical properties of the prosthesis. The mechanical characteristics of bone mineral density screw and traditional screw were compared by finite element analysis method, and redesigned by topology optimization. The direction of the newly proposed screw channel was the posterolateral entrance of the auricular surface, ending at the contralateral sacral cape. Compared to the original group, the maximum stress of the optimized prosthesis was decreased by 24.39%, the maximum stress of the sacrum in the optimized group was decreased by 27.23%, and the average strain energy density of the sacrum in the optimized group was increased by 8.43%. On the surface of screw and connecting plate, the area with micromotion more than 28 μm is reduced by 12.17%. On the screw surface, the area with micromotion more than 28 μm is reduced by 22.9%. The newly determined screw channel and optimized prosthesis design can effectively improve the biomechanical properties of a prosthesis and the microenvironment of osseointegration. This method can provide a reference for the fixation of prostheses in clinical pelvic reconstruction.

Indexed as

bone mineral densityhemipelvic prosthesisporous structurescrew channeltopological optimization

Identifiers

PMID35706507
PMCPMC9189365
OpenAlexW4281634024

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.