Evidence map›Paper›PMID 35706129›Full record

ArticleOrthopaedic surgery2022

Biomechanical Study of Intramedullary Versus Extramedullary Implants for Four Types of Subtrochanteric Femoral Fracture.

Jie Wang, Haobo Jia, Xinlong Ma, Jianxiong Ma, Bin Lu, Haohao Bai, Ying Wang

Open access · goldAbstract read
In one paragraph

Article in Orthopaedic surgery, 2022. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 3 papers.

0numbers the graph read from it
0cells of the map it votes in
3citing papers in PubMed
1.7field-weighted citation impact, top 16% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

3 citing papers in PubMed, 9 citations in OpenAlex.

  1. Article
  2. Article
  3. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

7 authors at 1 institution in 1 country.

Jie WangDepartment of Orthopaedics, Tianjin Hospital, Tianjin, China.
Haobo JiaDepartment of Orthopaedics, Tianjin Hospital, Tianjin, China.
Xinlong MaDepartment of Orthopaedics, Tianjin Hospital, Tianjin, China.ORCID https://orcid.org/0000-0002-8250-0994
Jianxiong MaDepartment of Orthopaedics Institute, Tianjin Hospital, Tianjin, China.
Bin LuDepartment of Orthopaedics Institute, Tianjin Hospital, Tianjin, China.
Haohao BaiDepartment of Orthopaedics Institute, Tianjin Hospital, Tianjin, China.
Ying WangDepartment of Orthopaedics Institute, Tianjin Hospital, Tianjin, China.
Tianjin Hospital · CN

Funding

National Natural Science Foundation of China 81601893Natural Science Foundation of Tianjin City 17JCQNJC10900Tianjin Enterprise Postdoctoral Innovation Project TJQYBSH2017013
6 · The paper itself

Abstract

objectivesTo compare the biomechanical performance of proximal femoral nail anti-rotation (PFNA), the "upside-down" less invasive plating system (LISS), and proximal femoral locking plate (PFLP) in fixing different fracture models of subtrochanteric fractures.

methodsThirty composite femurs were divided into three equal groups (PFNA, PFLP, and reverse LISS). The implant-femur constructs were tested under axial compression load (0-1400 N) from models I to IV, which represented the Seinsheimer type I subtrochanteric fracture, type IIIa subtrochanteric fracture with the posteromedial fragment reduced; type IIIa subtrochanteric fracture with the posteromedial fragment lost; and type IV subtrochanteric fracture, respectively. Axial stiffness was analyzed for each group. Each group was then divided into two subgroups, one of which underwent torsional and axial compression failure testing, while the other subgroup underwent axial compression fatigue testing. The torsional stiffness, failure load, and cycles to failure were analyzed.

resultsPFNA had the highest axial stiffness (F = 761.265, p < 0.0001) and failure load (F = 48.801, p < 0.0001) in model IV. The axial stiffness and failure load of the PFLP were significantly higher than those of the LISS (p < 0.0001, p = 0.001). However, no significant difference in axial stiffness was found between models I to III (model I: F = 2.439, p = 0.106; model II: F = 2.745, p = 0.082; model III: F = 0.852, p = 0.438) or torsional stiffness in model IV (F = 1.784, p = 0.187). In fatigue testing, PFNA did not suffer from construct failure after 90,000 cycles of axial compression. PFLP and LISS were damaged within 14,000 cycles, although LISS withstood more cycles than PFLP (t = 3.328, p = 0.01).

conclusionThe axial stiffness of the three implants was similar in models I to III. The biomechanical properties of PFNA were the best of the three implants in terms of axial stiffness, failure load, and fatigue testing cycles in model IV. The axial stiffness and failure load of the PFLP were better than those of the reverse LISS, but PFLP had fewer cycles in the fatigue tests than the reverse LISS.

Indexed as

Femoral FracturesFracture FixationBiomechanical PhenomenaBone NailsBone PlatesFracture Fixation, IntramedullaryHumansBiomechanicalExtramedullary fixationFatigue testIntramedullary nailSubtrochanteric fractures

Identifiers

PMID35706129
PMCPMC9363741
OpenAlexW4282979475

What OpenQuestion holds

Textmetadata
LicenceCC BY-NC-ND
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.