Evidence map›Paper›PMID 35705952›Full record

ArticleBMC musculoskeletal disorders2022

Sagittal femoral bowing contributes to distal femoral valgus angle deviation in malrotated preoperative radiographs.

Yasuhiko Kokubu, Shinya Kawahara, Satoshi Hamai, Yukio Akasaki, Hidetoshi Tsushima, Kenta Momii, Yasuharu Nakashima

Open access · goldAbstract read
In one paragraph

Article in BMC musculoskeletal disorders, 2022. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 2 papers.

0numbers the graph read from it
0cells of the map it votes in
2citing papers in PubMed
0.4field-weighted citation impact, top 38% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

2 citing papers in PubMed, 2 citations in OpenAlex.

  1. Article
  2. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

7 authors at 1 institution in 1 country.

Yasuhiko KokubuDepartment of Orthopaedic Surgery, Graduate School of Medical Sciences, Kyushu University, 3-1-1 Maidashi, Higashi-ku, Fukuoka, 812-8582, Japan.
Shinya KawaharaDepartment of Orthopaedic Surgery, Graduate School of Medical Sciences, Kyushu University, 3-1-1 Maidashi, Higashi-ku, Fukuoka, 812-8582, Japan. kawahara@ortho.med.kyushu-u.ac.jp.
Satoshi HamaiDepartment of Orthopaedic Surgery, Graduate School of Medical Sciences, Kyushu University, 3-1-1 Maidashi, Higashi-ku, Fukuoka, 812-8582, Japan.
Yukio AkasakiDepartment of Orthopaedic Surgery, Graduate School of Medical Sciences, Kyushu University, 3-1-1 Maidashi, Higashi-ku, Fukuoka, 812-8582, Japan.
Hidetoshi TsushimaDepartment of Orthopaedic Surgery, Graduate School of Medical Sciences, Kyushu University, 3-1-1 Maidashi, Higashi-ku, Fukuoka, 812-8582, Japan.
Kenta MomiiDepartment of Orthopaedic Surgery, Graduate School of Medical Sciences, Kyushu University, 3-1-1 Maidashi, Higashi-ku, Fukuoka, 812-8582, Japan.
Yasuharu NakashimaDepartment of Orthopaedic Surgery, Graduate School of Medical Sciences, Kyushu University, 3-1-1 Maidashi, Higashi-ku, Fukuoka, 812-8582, Japan.
Kyushu University · JP

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

backgroundThe coronal whole-leg radiograph is generally used for preoperative planning in total knee arthroplasty. The distal femoral valgus angle (DFVA) is measured for distal femoral bone resection using an intramedullary guide rod. The effect of coronal and sagittal femoral shaft bowing on DFVA measurement in the presence of malrotation or knee flexion contracture has not been well reported. The objectives of this study were: (1) to investigate the effects of whole-leg malrotation and knee flexion contracture on the DFVA in detail, (2) to determine the additional effect of coronal or sagittal femoral shaft bowing.

methodsWe studied 100 consecutive varus and 100 valgus knees that underwent total or unicompartmental knee arthroplasty. Preoperative CT scans were used to create digitally reconstructed radiography (DRR) images in neutral rotation (NR, parallel to the surgical epicondylar axis), and at 5° and 10° external rotation (ER) and internal rotation (IR). The images were also reconstructed at 10° femoral flexion. The DFVA was evaluated in each DRR image, and the angular variation due to lower limb malposition was investigated.

resultsThe DFVA increased as the DRR image shifted from IR to ER, and all angles increased further from extension to 10° flexion. The DFVA variation in each position was 1.3° on average. A larger variation than 2° was seen in 12% of all. Multivariate regression analysis showed that sagittal femoral shaft bowing was independently associated with a large variation of DFVA. Receiver operating characteristic analysis showed that more than 12° of sagittal bowing caused the variation.

conclusionIf femoral sagittal bowing is more than 12°, close attention should be paid to the lower limb position when taking whole-leg radiographs. Preoperative planning with whole-leg CT data should be considered.

Indexed as

ContractureGenu VarumOsteoarthritis, KneeFemurHumansKnee JointLower ExtremityRadiographyDistal femoral valgus angleFemoral shaft bowingMalrotationTotal knee arthroplastyWhole-leg radiography

Identifiers

PMID35705952
PMCPMC9199152
OpenAlexW4282918587

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.