ArticleArchives of orthopaedic and trauma surgery2023
Discharging the medial knee compartment: comparison of pressure distribution and kinematic shifting after implantation of an extra-capsular absorber system (ATLAS) and open-wedge high tibial osteotomy-a biomechanical in vitro analysis.
Article in Archives of orthopaedic and trauma surgery, 2023. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 2 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
2 citing papers in PubMed, 5 citations in OpenAlex.
- Implantable Shock Absorber: Breakthrough or Hype?Current reviews in musculoskeletal medicine · 2026Review
- A novel geometrical planning method to restore knee joint obliquity in double-level osteotomies.Archives of orthopaedic and trauma surgery · 2023Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
9 authors at 3 institutions in 2 countries.
Funding
No grant is acknowledged in the PubMed record.
Abstract
purposeYoung and active patients suffering early degenerative changes of the medial compartment with an underlying straight-leg axis do face a therapeutical gap as unloading of the medial compartment cannot be achieved by high tibial osteotomy. Extracapsular absorbing implants were developed to close this existing therapeutical gap. Purpose of the present cadaveric biomechanical study was to compare the unloading effect of the knee joint after implantation of an extra-articular absorber system (ATLAS) in comparison to open-wedge high tibial osteotomy (OW-HTO) under physiological conditions. The hypothesis of the study was that implantation of an extra-capsular absorber results in an unloading effect comparable to the one achievable with OW-HTO.
methodsEight fresh-frozen cadaveric knees were tested under isokinetic flexion-extension motions and physiological loading using a biomechanical knee simulator. Tibiofemoral area contact and peak contact pressures were measured using pressure-sensitive film in the untreated medial compartment. The tibiofemoral superior-inferior, latero-medial translation and varus/valgus rotation were measured with a 3D tracking system Polaris. Pressures and kinematics changes were measured after native testing, ATLAS System implantation and OW-HTO (5° and 10° correction angles) performed with an angular stable internal fixator (TomoFix).
resultsThe absorber device decreased the pressure in the medial compartment near full extension moments. Implantation of the ATLAS absorbing system according to the manufacturers' instruction did not result in a significant unloading effect. Deviating from the surgery manual provided by the manufacturer the implantation of a larger spring size while applying varus stress before releasing the absorber resulted in a significant pressure diminution. Contact pressure decreased significantly Δ0.20 ± 0.04 MPa p = 0.044. Performing the OW-HTO in 5° correction angle resulted in significant decreased contact pressure (Δ0.25 ± 0.10 MPa, p = 0.0036) and peak contact pressure (Δ0.39 ± 0.38 MPa, p = 0.029) compared with the native test cycle. With a 10° correction angle, OW-HTO significantly decreased area contact pressure by Δ0.32 ± 0.09 MPa, p = 0.006 and peak contact pressure by Δ0.48 ± 0.12 MPa, p = 0.0654 compared to OW-HTO 5°. Surgical treatment did not result in kinematic changes regarding the superior-inferior translation of the medial joint section. A significant difference was observed for the translation towards the lateral compartment for the ATLAS system Δ1.31 ± 0.54 MPa p = 0.022 and the osteotomy Δ3.51 ± 0.92 MPa p = 0.001. Furthermore, significant shifting varus to valgus rotation of the treated knee joint was verified for HTO 5° about Δ2.97-3.69° and for HTO 10° Δ4.11-5.23° (pHTO 5 = 0.0012; pHTO 10 = 0.0007) over the entire extension cycle.
conclusionOW-HTO results in a significant unloading of the medial compartment. Implantation of an extra-capsular absorbing device did not result in a significant unloading until the implantation technique was applied against the manufacturer's recommendation. While the clinical difficulty for young and active patients with straight-leg axis and early degenerative changes of the medial compartment persists further biomechanical research to develop sufficient unloading devices is required.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.