Evidence map›Paper›PMID 35698801›Full record

ArticleBone & joint open2022

High rate of tibial debonding and failure in a popular knee replacement : a follow-up review.

David Keohane, Gerard A Sheridan, Eric Masterson

Open access · goldAbstract read
In one paragraph

Article in Bone & joint open, 2022. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 8 papers.

0numbers the graph read from it
0cells of the map it votes in
8citing papers in PubMed
5.2field-weighted citation impact, top 4% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

8 citing papers in PubMed, 25 citations in OpenAlex.

  1. Article
  2. Article
  3. Article
  4. Article
  5. Article
  6. Article
  7. Article
  8. Does lucency equate to revision? A five-year retrospective review of Attune and Triathlon total knee arthroplasty.Knee surgery, sports traumatology, arthroscopy : official journal of the ESSKA · 2023
    Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

3 authors at 2 institutions in 1 country.

David KeohaneDepartment of Trauma and Orthopaedics, University Hospital Limerick, Limerick, Ireland.ORCID 0000-0002-7242-9493
Gerard A SheridanDepartment of Trauma and Orthopaedics, Royal College of Surgeons Ireland, Dublin, Ireland.ORCID 0000-0003-0970-3274
Eric MastersonDepartment of Trauma and Orthopaedics, University Hospital Limerick, Limerick, Ireland.
University Hospital Limerick · IERoyal College of Surgeons in Ireland · IE

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

aimsTotal knee arthroplasty (TKA) is a common and safe orthopaedic procedure. Zimmer Biomet's NexGen is the second most popular brand of implant used in the UK. The primary cause of revision after the first year is aseptic loosening. We present our experience of using this implant, with significant concerns around its performance with regards early aseptic loosening of the tibial component.

methodsA retrospective, single-surgeon review was carried out of all of the NexGen Legacy Posterior Stabilized (LPS) TKAs performed in this institute. The specific model used for the index procedures was the NexGen Complete Knee System (Legacy Knee-Posterior Stabilized LPS-Flex Articular Surface, LPS-Flex Femoral Component Option, and Stemmed Nonaugmentable Tibial Component Option).

resultsBetween 2013 and 2016, 352 NexGen TKAs were carried out on 331 patients. A total of 62 TKAs have been revised to date, giving an all-cause revision rate of 17.6% at a minimum of five years. Three of these revisions were due to infection. Overall, 59 of the revisions were performed for aseptic loosening (16.7%) of the tibial component. The tibial component was removed intraoperatively without instrumentation due to significant tibial debonding between the implant-cement interface.

conclusionWhile overall, we believe that early aseptic loosening is multi-factorial in nature, the significantly high aseptic revision rate, as seen by an experienced fellowship-trained arthroplasty surgeon, has led us to believe that there is a fundamental issue with this NexGen implant design. Continued implant surveillance and rigorous review across all regions using this particular implant is warranted based on the concerning findings described here. Cite this article:

Indexed as

arthroplasty surgeonaseptic looseningAseptic LooseningEarly Implant FailureFemoral ComponentInfectionknee arthroplastieskneesNexGenorthopaedic proceduresingle-surgeontibial componentsTibial Tray FailureTotal Knee Arthroplastytotal knee arthroplasty (TKA)Zimmer

Identifiers

PMID35698801
PMCPMC9233423
OpenAlexW4282833607

What OpenQuestion holds

Textmetadata
LicenceCC BY-NC-ND
Read underepoch 390

Registered trials

None linked