Performance evaluation of dedicated brain PET scanner with motion correction system.

Yuya Onishi, Takashi Isobe, Masanori Ito, Fumio Hashimoto, Tomohide Omura, Etsuji Yoshikawa

Abstract read
PubMed Publisher
In one paragraph

Article in Annals of nuclear medicine, 2022. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 8 papers.

0numbers the graph read from it
0cells of the map it votes in
8citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

8 citing papers in PubMed.

  1. Quantitative Accuracy Assessment of the NeuroEXPLORER for Diverse Imaging Applications: Moving Beyond Standard Evaluations.Journal of nuclear medicine : official publication, Society of Nuclear Medicine · 2025
    Article
  2. Article
  3. Review
  4. Review
  5. Review
  6. Article
  7. Review
  8. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

6 authors.

Yuya Onishi *Central Research Laboratory, Hamamatsu Photonics K. K, Hamamatsu, 434-8601, Japan. yuya.onishi@hpk.co.jp.ORCID http://orcid.org/0000-0001-9715-4636
Takashi Isobe *Central Research Laboratory, Hamamatsu Photonics K. K, Hamamatsu, 434-8601, Japan.
Masanori Ito *Global Strategic Challenge Center, Hamamatsu Photonics K.K, Hamamatsu, 434-8601, Japan.
Fumio HashimotoCentral Research Laboratory, Hamamatsu Photonics K. K, Hamamatsu, 434-8601, Japan.
Tomohide OmuraCentral Research Laboratory, Hamamatsu Photonics K. K, Hamamatsu, 434-8601, Japan.
Etsuji YoshikawaCentral Research Laboratory, Hamamatsu Photonics K. K, Hamamatsu, 434-8601, Japan.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

objectiveVarious motion correction (MC) algorithms for positron emission tomography (PET) have been proposed to accelerate the diagnostic performance and research in brain activity and neurology. We have incorporated MC system-based optical motion tracking into the brain-dedicated time-of-flight PET scanner. In this study, we evaluate the performance characteristics of the developed PET scanner when performing MC in accordance with the standards and guidelines for the brain PET scanner.

methodsWe evaluate the spatial resolution, scatter fraction, count rate characteristics, sensitivity, and image quality of PET images. The MC evaluation is measured in terms of the spatial resolution and image quality that affect movement.

resultsIn the basic performance evaluation, the average spatial resolution by iterative reconstruction was 2.2 mm at 10 mm offset position. The measured peak noise equivalent count rate was 38.0 kcps at 16.7 kBq/mL. The scatter fraction and system sensitivity were 43.9% and 22.4 cps/(Bq/mL), respectively. The image contrast recovery was between 43.2% (10 mm sphere) and 72.0% (37 mm sphere). In the MC performance evaluation, the average spatial resolution was 2.7 mm at 10 mm offset position, when the phantom stage with the point source translates to ± 15 mm along the y-axis. The image contrast recovery was between 34.2 % (10 mm sphere) and 66.8 % (37 mm sphere).

conclusionsThe reconstructed images using MC were restored to their nearly identical state as those at rest. Therefore, it is concluded that this scanner can observe more natural brain activity.

Indexed as

Positron-Emission TomographyTomography, X-Ray ComputedBrainHeadHumansPhantoms, ImagingBrain-dedicated positron emission tomographyFree movingMotion correctionPerformance evaluation