Evidence map›Paper›PMID 35696132›Full record

ArticleTranslational vision science & technology2022

Characteristics of Pupil Offset in Young Asian Adults With Mild-Moderate and High Myopia.

Shengshu Sun, Zhanglin Liu, Yuan Wu, Xiaowen Sun, Shaozhen Zhao, Yue Huang

Open access · goldAbstract read
In one paragraph

Article in Translational vision science & technology, 2022. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 3 papers.

0numbers the graph read from it
0cells of the map it votes in
3citing papers in PubMed
0.7field-weighted citation impact, top 32% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

3 citing papers in PubMed, 5 citations in OpenAlex.

  1. Article
  2. Article
  3. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

6 authors at 2 institutions in 1 country.

Shengshu SunTianjin Medical University Eye Hospital, College of Optometry, Institute of Ophthalmology, National Clinical Medical Research Center for Eye, Ear, Nose and Throat Diseases, Tianjin Branch, Tianjin Key Laboratory of Retinal Function and Diseases, Tianjin, China.
Zhanglin LiuTianjin Medical University Eye Hospital, College of Optometry, Institute of Ophthalmology, National Clinical Medical Research Center for Eye, Ear, Nose and Throat Diseases, Tianjin Branch, Tianjin Key Laboratory of Retinal Function and Diseases, Tianjin, China.
Yuan WuTianjin Medical University Eye Hospital, College of Optometry, Institute of Ophthalmology, National Clinical Medical Research Center for Eye, Ear, Nose and Throat Diseases, Tianjin Branch, Tianjin Key Laboratory of Retinal Function and Diseases, Tianjin, China.
Xiaowen SunTianjin Medical University Eye Hospital, College of Optometry, Institute of Ophthalmology, National Clinical Medical Research Center for Eye, Ear, Nose and Throat Diseases, Tianjin Branch, Tianjin Key Laboratory of Retinal Function and Diseases, Tianjin, China.
Shaozhen ZhaoTianjin Medical University Eye Hospital, College of Optometry, Institute of Ophthalmology, National Clinical Medical Research Center for Eye, Ear, Nose and Throat Diseases, Tianjin Branch, Tianjin Key Laboratory of Retinal Function and Diseases, Tianjin, China.
Yue HuangTianjin Medical University Eye Hospital, College of Optometry, Institute of Ophthalmology, National Clinical Medical Research Center for Eye, Ear, Nose and Throat Diseases, Tianjin Branch, Tianjin Key Laboratory of Retinal Function and Diseases, Tianjin, China.
Tianjin Medical University · CNTianjin Medical University Eye Hospital · CN

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Purpose: The purpose of this study was to explore the characteristics of pupil offset in young Asian adults with myopia. Methods: In total, 1200 eyes (600 young adults, 18-35 years old) were divided into mild-moderate and high groups according to equivalent spherical diopters (SEQ). The pupil offset and its X and Y components were compared between the groups. Linear correlation was analyzed among pupil offset, X and Y components, and SEQ. Multiple linear regression analysis was conducted for pupil offset and eye parameters. Results: The mean age of all subjects was 22.5 ± 4.8 years. The mean magnitude of the pupil offset (0.18 ± 0.09 mm vs. 0.15 ± 0.08 mm) and Y component (0.12 ± 0.08 mm vs. 0.10 ± 0.07 mm) were larger in the high group than in the mild-moderate group (P < 0.05). The magnitude of pupil offset, X and Y components, and SEQ were positively correlated. The pupil center (PC) of the right eye in the mild-moderate group was mainly superotemporal to the corneal vertex and mainly superonasal for the left eye and both eyes in the high group. Multiple linear regression analysis revealed that the magnitude of pupil offset correlated with central corneal thickness, intraocular pressure, and mean corneal curvature (P < 0.05). Conclusions: The magnitude of the pupil offset that correlated with partial eye parameters and its X and Y components increased as the SEQ increased, and the PC gradually shifted toward the superonasal direction in young Asian adults with myopia. Translational Relevance: Subjects with high myopia with a larger pupil offset should be considered for better postoperative visual quality during refractive surgery.

Indexed as

Keratomileusis, Laser In SituMyopiaAdolescentAdultCorneaHumansPupilVisual AcuityYoung Adult

Identifiers

PMID35696132
PMCPMC9202332
OpenAlexW4282585035

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.