Evidence map›Paper›PMID 35695968›Full record

ArticleEuropean spine journal : official publication of the European Spine Society, the European Spinal Deformity Society, and the European Section of the Cervical Spine Research Society2022

A comparison of the inflammatory host response to particulate debris adjacent to unlocked and locked screws of a growth guidance system for early onset scoliosis.

Jeffrey M Toth, Felix Ankomah, Noriaki Kawakami, Koki Uno

Abstract read
PubMed Publisher
In one paragraph

Article in European spine journal : official publication of the European Spine Society, the European Spinal Deformity Society, and the European Section of the Cervical Spine Research Society, 2022. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 3 papers.

0numbers the graph read from it
0cells of the map it votes in
3citing papers in PubMed
0.9field-weighted citation impact, top 27% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

3 citing papers in PubMed, 4 citations in OpenAlex.

  1. Review
  2. Tissue response following implantation with the posterior dynamic distraction device (PDDD) in adolescent idiopathic scoliosis (AIS).European spine journal : official publication of the European Spine Society, the European Spinal Deformity Society, and the European Section of the Cervical Spine Research Society · 2024
    Article
  3. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

4 authors at 3 institutions in 2 countries.

Jeffrey M TothDepartment of Orthopaedic Surgery, The Medical College of Wisconsin Inc., 8701 W. Watertown Plank Road, Box 26509, Milwaukee, WI, 53226-0509, USA. jtoth@mcw.edu.ORCID 0000-0003-3000-7230
Felix AnkomahDepartment of Orthopaedic Surgery, The Medical College of Wisconsin Inc., 8701 W. Watertown Plank Road, Box 26509, Milwaukee, WI, 53226-0509, USA.
Noriaki KawakamiIchinomiya Nishi Hospital, Kaimei, Hira -1, Ichinomiya, Aichi, 494-0001, Japan.
Koki UnoKobe Medical Center, Suma Ward, Nishiochiai, 3 Chome-1-1, Kobe, Hyogo, 654-0155, Japan.
Kobe Medical Center · JPMarquette University · USMedical College of Wisconsin · US

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

purposeThe SHILLA™ Growth Guidance system is a stainless-steel rod and screw system used for Early Onset Scoliosis which incorporates a unique flanged set screw designed to capture the rod, while allowing it to slide as the patient grows. Concomitant with this design is the potential for generation of wear debris and for an inflammatory host response. We hypothesized that the magnitude of the host response adjacent to the unlocked screws and rods would be greater than the host response to the locked rod/screws.

methodsSeven tissue samples adjacent to locked (3) and unlocked screws (4) from three SHILLA patients (mean implantation time of 19 post-operative months) with infantile idiopathic scoliosis were obtained as part of an explant analysis protocol during a PMDA-approved clinical trial in Japan. Gross appearance, high-resolution radiographs, and histology were assessed. ISO Standard 10993 Part 6 was used to assess the host response.

resultsAll three locked screw had no metallosis. In contrast, metallosis for unlocked screw tissue samples were rated as "ubiquitous" (2/4), "focal" (1/4), or "absent" (1/4). Microscopic metallic debris was found intracellularly and within interstices of fibrous connective tissues more frequently adjacent to unlocked screws compared to locked screws. Cell type and population scoring consistently showed a modestly larger inflammatory response (macrophages) in the unlocked tissue samples.

conclusionsThe peri-prosthetic tissue response to the unlocked rods/screws had a higher reactivity grade (slight reaction, Δ = 4.0) per ISO 10993 Part 6 compared to the locked screws in three patients with the SHILLA™ Growth Guidance scoliosis system.

Indexed as

ScoliosisSpinal FusionBone ScrewsHumansJapanRadiographyStainless SteelStainless SteelBiocompatibility testingExplant studyHistologyHost responseISO 10993 Part 6Metallic wear debrisProstheses and implantsScoliosisSHILLA®Spinal instrumentationStainless steel

Identifiers

PMID35695968
OpenAlexW4282552622

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.