Observational studyJournal of clinical monitoring and computing2023
Intra-abdominal hypertension in cardiac surgery patients: a multicenter observational sub-study of the Accuryn registry.
Observational study in Journal of clinical monitoring and computing, 2023. The graph could read no effect estimate from its abstract, so it casts no vote on the map. It is linked to 2 registered trials, which are not on this map. Cited by 18 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Physiologic Signals and Signatures With the Accuryn Monitoring System - A Retrospective and Prospective Analysis (The Accuryn Registry)
Prognostic Value of Continuous Intra-abdominal Pressure (CIAP) and Continuous Abdominal Perfusion Pressure (CAPP) Monitoring for Acute Kidney Injury (AKI) Prediuction in Patients Undergoing Coronary Artery Bypass Graft (CABG) Surgery
Who cites it
18 citing papers in PubMed, 31 citations in OpenAlex.
- Clinical validation of an intra-abdominal pressure monitoring system by comparison with pneumoperitoneum pressure.Journal of clinical monitoring and computing · 2026Article
- Microwave Radar Sensing for Non-Invasive Intra-Abdominal Pressure Monitoring: A Simulation-Based Analysis with Phantom Testing.Sensors (Basel, Switzerland) · 2026Article
- Development and Validation of an Optical Sensor-Based Automated Urine Flow Meter for Real-Time Patient Monitoring.Sensors (Basel, Switzerland) · 2026Article
- Cardiovascular effects of intra-abdominal hypertension: current perspectives.Anaesthesiology intensive therapy · 2025Review
- Variation and accuracy of intra-abdominal pressure measurement in different body positions: a prospective study.World journal of emergency surgery : WJES · 2025Article
- Awareness, knowledge and practices related to intra-abdominal hypertension and abdominal compartment syndrome among intensive care providers: a systematic scoping review.Annals of intensive care · 2025Review
- Risk factors of intraabdominal hypertension in cardiac surgery: A systematic review and meta-analysis.Turk gogus kalp damar cerrahisi dergisi · 2025Article
- International cross-sectional survey on current and updated definitions of intra-abdominal hypertension and abdominal compartment syndrome.World journal of emergency surgery : WJES · 2024Article
- Optimization of kidney function in cardiac surgery patients with intra-abdominal hypertension: expert opinion.Perioperative medicine (London, England) · 2024Review
- Urine output is an early and strong predictor of acute kidney injury and associated mortality: a systematic literature review of 50 clinical studies.Annals of intensive care · 2024Review
- Evaluation of the TraumaGuard Balloon-in-Balloon Catheter Design for Intra-Abdominal Pressure Monitoring: Insights from Pig and Human Cadaver Studies.Sensors (Basel, Switzerland) · 2023Article
- Article
- Assessment of Intra-Abdominal Pressure with a Novel Continuous Bladder Pressure Monitor-A Clinical Validation Study.Life (Basel, Switzerland) · 2023Article
- A Retrospective, Observational Study of Catheter-Associated Urinary Tract Infection Events Post-Implementation of a Novel Urinary Catheter System with Active Drain Line Clearance and Automated Intra-Abdominal Pressure Monitoring.Life (Basel, Switzerland) · 2022Article
- Continuous intra-abdominal pressure: is it ready for prime time?Intensive care medicine · 2022Article
- Pre-Clinical Validation of A Novel Continuous Intra-Abdominal Pressure Measurement Equipment (SERENNO).Life (Basel, Switzerland) · 2022Article
- Article
- Beware the gorilla that may come with severe pancreatitis.Proceedings (Baylor University. Medical Center)Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
8 authors at 5 institutions in 2 countries.
Funding
No grant is acknowledged in the PubMed record.
Abstract
Intra-abdominal hypertension (IAH) is frequently present in the critically ill and is associated with increased morbidity and mortality. Conventionally, intermittent 'spot-check' manual measurements of bladder pressure in those perceived as high risk are used as surrogates for intra-abdominal pressure (IAP). True patterns of IAH remain unknown. We explored the incidence of IAH in cardiac surgery patients and describe the intra-and postoperative course of IAP using a novel, high frequency, automated bladder pressure measurement system. Sub-analysis of a prospective, multicenter, observational study (NCT04669548) conducted in three large academic medical centers. Continuous urinary output (CUO) and IAP measurements were observed using the Accuryn Monitoring System (Potrero Medical, Hayward, CA). Data collected included demographics, hemodynamic support, and high-frequency IAP and CUO. One Hundred Thirty-Seven cardiac surgery patients were analyzed intraoperatively and followed 48 h postoperatively in the intensive care unit. Median age was 66.4 [58.3, 72.0] years, and 61% were men. Median Foley catheter dwell time was 56.0 [46.8, 77.5] hours, and median baseline IAP was 6.3 [4.0, 8.1] mmHg. 93% (128/137) of patients were in IAH grade I, 82% (113/137) in grade II, 39% (53/137) in grade III, and 5% (7/137) in grade IV for at least 12 cumulative hours. For maximum consecutive duration of IAH, 84% (115/137) of patients spent at least 12 h in grade I, 62% (85/137) in grade II, 18% (25/137) in grade III, and 2% (3/137) in grade IV IAH. During the first 48 h after cardiac surgery, IAH is common and persistent. Improved and automated monitoring of IAP will increase the detection of IAH-which normally would remain undetected using traditional intermittent monitoring methods.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.