ArticleInternational journal of sports physical therapy2022

Reliability and Validity of the ActivForce Digital Dynamometer in Assessing Shoulder Muscle Force across Different User Experience Levels.

Christos Karagiannopoulos, Sean Griech, Brian Leggin

Abstract read
In one paragraph

Article in International journal of sports physical therapy, 2022. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 24 papers.

0numbers the graph read from it
0cells of the map it votes in
24citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

24 citing papers in PubMed.

  1. Trial
  2. Article
  3. Article
  4. Article
  5. Article
  6. Article
  7. Article
  8. Article
  9. Article
  10. Article
  11. Article
  12. Article
  13. Article
  14. Article
  15. Article
  16. Article
  17. Article
  18. Article
  19. Article
  20. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

3 authors.

Christos KaragiannopoulosDoctor of Physical Therapy Program, DeSales University.ORCID 0000-0002-8166-687X
Sean GriechDoctor of Physical Therapy Program, DeSales University.ORCID 0000-0003-1113-5421
Brian LegginPenn Therapy and Fitness, Good Shepherd Penn Partners.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Background: Currently available hand-held dynamometers (HHD) offer a more objective and reliable assessment of muscle force production as compared to a manual muscle test (MMT). Yet, their clinical utility is limited due to high cost. The ActivForce (AF) digital dynamometer is a new low-cost HHD with unknown psychometric properties, and its utilization may benefit clinical practice. Hypothesis/Purpose: This study aimed to determine the AF intra- and inter-tester reliabilities, standard error of measurement (SEM), minimal detectable change (MDC), and criterion validity for assessing shoulder isometric force as compared to the microFET2 (MF2) across testers with different experiences. Design: Descriptive observational study. Methods: A convenience sample of 29 healthy adults were assessed twice by each of three testers (two experienced clinicians and a novice PT student) on shoulder external rotation (ER), internal rotation (IR), and forward elevation (FE) using both the AF and MF2 devices. Tester, HHD, and shoulder motion assignment orders were randomized. All testing was performed in a standardized seated position. ER and IR were tested with the shoulder fully adducted. FE was tested at 45° at the scapular plane. All testing and rest periods between testers and tested motions were standardized and monitored via a stopwatch. Results: Both devices had high intra- [ ER (.95-.98), IR (.97 - .99), FE (.96 - .99)] and inter-tester [ ER (.85-.96), IR (.95 - .97), FE (.88 - .95)] intraclass correlation coefficient (ICC) with comparable intra- (1.68-1.80) and inter-tester (2.36-2.98) SEM, and intra- (4.64-4.97) and inter-tester (6.50-8.24) MDC values across all motions. Tester experience did not affect these values. High (.89-.93) statistically significant Pearson correlations were found between HHDs for all shoulder motions. Conclusion: Both the AF and MF2 HHDs were found to have high reliability levels across all shoulder motions regardless of tester clinical experience. The AF was also found to be valid for measuring shoulder isometric force production compared to the criterion standard device, the MF2. Its low-cost and electronic accessibility features may promote better compliance for clinicians using dynamometry to objectively assess and store muscle force data in a cost-effective manner. Level of Evidence: 3.

Indexed as

ActivForceclinical experiencehand-held dynamometermicroFET2psychometric properties

Identifiers

PMID35693865
PMCPMC9159718

What OpenQuestion holds

Textmetadata
LicenceCC BY-NC
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.