ArticleJBJS essential surgical techniques
Suture Anchor-Enhanced Medial Capsulorrhaphy of the Great Toe.
Article in JBJS essential surgical techniques. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
1 citing paper in PubMed, 1 citations in OpenAlex.
- Modified Medial Capsulorrhaphy Using Figure-of-Eight Suture in Hallux Valgus Correction Surgery.Advances in orthopedics · 2024Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
6 authors at 1 institution in 1 country.
Funding
No grant is acknowledged in the PubMed record.
Abstract
The suture anchor-enhanced medial capsulorrhaphy of the great toe is utilized as an adjuvant procedure to proximal and distal osteotomies for the treatment of hallux valgus. In traditional open techniques, hallux valgus repair requires both osseous correction along with shortening of the capsule on the medial side of the metatarsophalangeal joint. Osseous correction typically corrects the intermetatarsal angle, whereas capsular correction maintains the hallux valgus angle Description: A standard medial approach to the 1st metatarsophalangeal joint is performed. A medial midline horizontal capsulotomy is performed starting just proximal to the medial eminence and extending distally to the base of the proximal phalanx. Once the concomitant osseous and soft-tissue procedures are completed, a vertical capsulotomy is made in the inferior capsular flap at the level of the metatarsophalangeal joint in a manner perpendicular to the first ray in order to form an L shape. A 3 to 4-mm wedge of capsule is formed near the base of the vertical limb, running obliquely to the horizontal limb, and is excised. Optionally, the free limbs of the inferior capsule are imbricated. A unicortical hole is then drilled in the first metatarsal head, and a 2.7-mm outer diameter by 7-mm deep suture anchor with 2-0 FiberWire (Arthrex) is placed. The free ends of the suture are then utilized to close the horizontal capsulotomy in a running-locking interrupted fashion. Fluoroscopic imaging is performed throughout the procedure to prevent overcorrection and varus malignment. Alternatives: Alternative treatments include L-shaped capsulorrhaphy without suture anchor augmentation, dorsolinear capsulorrhaphy, Y-shaped capsulorrhaphy, and proximal hallux osteotomy or distal hallux osteotomy without capsulorrhaphy. Rationale: Anchor-enhanced capsulorrhaphy has been proven to assist in early maintenance of hallux valgus angle correction when combined with relevant distal osteotomy techniques. The anchor-enhanced capsulorrhaphy has an advantage over traditional capsulorrhaphy methods because it allows enhanced tightening of the capsule to the bone and, therefore, the potential for enhanced short-term maintenance. Additionally, the use of a running-locking interrupted suture technique reduces the number of suture knots required for capsular closure, potentially reducing the chance of complications such as suture granuloma formation. This technique is useful in all patients with hallux valgus deformity because it helps to provide durable deformity correction through additional modification of the soft tissues surrounding the 1st metatarsophalangeal joint. Expected Outcomes: Medial capsulorrhaphy has been shown to help with short-term reduction of the hallux valgus angle, both with and without the use of suture anchors Important Tips: Always excise a small capsular wedge to start with.Throughout the capsular tightening process, utilize clinical judgment and fluoroscopy to avoid pulling the hallux into varus malalignment.If varus is noted during plication of the plantar capsule, simply undo the tightening stitch.Because the majority of capsular tightening occurs at the first distal knot during the running horizontal capsular closure, if varus is noted, untie the knot and proceed with less correction.The extra cost of the suture anchor is a drawback but should be weighed against the enhanced durability of capsular correction compared with a traditional capsulorrhaphy.Always check the position of the suture anchor under fluoroscopy before proceeding with capsular closure in order to ensure proper deployment and adequate osseous purchase.Suture anchor failure can cause misleading radiographic presentation or joint impingement. Acronyms and Abbreviations: VAS = Visual analog scaleAOFAS = American Orthopaedic Foot & Ankle SocietyHV = Hallux valgusHVA = Hallux valgus angleMTP = Metatarsophalangeal jointDVT = Deep venous thrombosis.
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.