ArticleMagnetic resonance in medicine2022
Improved TSE imaging at ultrahigh field using nonlocalized efficiency RF shimming and acquisition modes optimized for refocused echoes (AMORE).
Article in Magnetic resonance in medicine, 2022. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 10 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
10 citing papers in PubMed, 11 citations in OpenAlex.
- Signal and Contrast Optimization With Predicted Excitations (SCOPE) for Accelerating Large FOV Body Imaging at UHF.Magnetic resonance in medicine · 2026Article
- 10.5 T In Vivo Head Imaging With Universal RF Shimming.Magnetic resonance in medicine · 2026Article
- Accurate MRF-Based 3D Multi-Channel BNMR in biomedicine · 2025Article
- A shielded 32-channel body transceiver array with integrated electronics for 7 T.Magnetic resonance in medicine · 2025Article
- A 128-channel receive array with enhanced signal-to-noise ratio performance for 10.5T brain imaging.Magnetic resonance in medicine · 2025Article
- Bilateral orthogonality generative acquisitions method for homogeneousMagnetic resonance in medicine · 2025Article
- Exploring in vivo human brain metabolism at 10.5 T: Initial insights from MR spectroscopic imaging.NeuroImage · 2025Article
- Universal modes: Calibration-free time-interleaved acquisition of modes.Magnetic resonance in medicine · 2024Article
- ImprovedMagnetic resonance in medicine · 2024Article
- Improved TSE imaging at ultrahigh field using nonlocalized efficiency RF shimming and acquisition modes optimized for refocused echoes (AMORE).Magnetic resonance in medicine · 2022Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
6 authors at 1 institution in 1 country.
Funding
Abstract
purposeTo develop and evaluate a novel RF shimming optimization strategy tailored to improve the transmit efficiency in turbo spin echo imaging when performing time-interleaved acquisition of modes (TIAMO) at ultrahigh fields. THEORY AND
methodsA nonlocalized efficiency shimming cost function is proposed and extended to perform TIAMO using acquisition modes optimized for refocused echoes (AMORE). The nonlocalized efficiency shimming was demonstrated in brain and knee imaging at 7 Tesla. Phantom and in vivo torso imaging studies were performed to compare the performance between AMORE and previously proposed TIAMO mode optimizations with and without localized constraints in turbo spin echo and gradient echo acquisitions.
resultsThe proposed nonlocalized efficiency RF shimming produced a circularly polarized-like field with fewer signal dropouts in the brain and knee. For larger targets, AMORE was used and required a significantly lower transmitter voltage to produce a similar contrast to existing TIAMO mode design approaches for turbo spin echo as well as gradient echo acquisitions. In vivo, AMORE effectively reduced signal dropout in the interior torso while providing more uniform contrast with reduced transmit power. A local constraint further improved performance for a target region while maintaining performance in the larger FOV.
conclusionAMORE based on the presented nonlocalized efficiency shimming cost function demonstrated improved contrast and SNR uniformity as well as increased transmit efficiency for both gradient echo and turbo spin echo acquisitions.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.