ArticleInternational orthopaedics2022
Volar locking plate fixation for distal radius fractures: did variable-angle plates make difference?
Article in International orthopaedics, 2022. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 12 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
12 citing papers in PubMed.
- Uniaxial versus polyaxial plating in tibial plateau fractures: a pilot prospective randomized controlled trial.European journal of orthopaedic surgery & traumatology : orthopedie traumatologie · 2025Trial
- Mechanical Performance of Monoaxial Versus Polyaxial Locked Plates for Bone Fracture Repair: A Review.Clinics in orthopedic surgery · 2026Review
- POSTOPERATIVE STABILITY AFTER VOLAR LOCKING PLATE IN DISTAL RADIUS FRACTURES.Acta ortopedica brasileira · 2026Article
- [Loss of Radial Height in Patients Undergoing Fixation with a Distal Volar Anatomical Locking Plate: A Retrospective Study in a Public Institution].Revista brasileira de ortopedia · 2025Article
- Loss of Radial Height in Patients Undergoing Fixation with a Distal Volar Anatomical Locking Plate: A Retrospective Study in a Public Institution.Revista brasileira de ortopedia · 2025Article
- Clinicoradiological Outcome of Variable Angle Volar Locking Plate in the Management of Distal Radius Fractures.Journal of orthopaedic case reports · 2025Article
- Assessment of the Mechanical Properties and Fragment Characteristics of a 3D-Printed Forearm Orthosis.Polymers · 2024Article
- Complications after volar plate synthesis for distal radius fractures.EFORT open reviews · 2024Article
- Choosing your implant - Volar locking plates - Horses for courses.Journal of orthopaedics · 2024Article
- Biomechanical analysis of a novel screw system with a variable locking angle in mandible angle fractures.Medical & biological engineering & computing · 2023Article
- Surgical options for distal radius fractures of type C in elderly patients over 65 years old: a comparison of external fixation with Kirschner wires and volar locking plate.Journal of orthopaedic surgery and research · 2023Article
- Evaluating the biomechanical performance of Ti6Al4V volar plates in patients with distal radius fractures.Frontiers in bioengineering and biotechnology · 2023Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
3 authors.
Funding
No grant is acknowledged in the PubMed record.
Abstract
purposeTwo different locking plate designs are now being used for volar plating of the distal radius fractures based on the freedom of screw direction; the fixed-angle, and the variable-angle (polyaxial) plates. We investigated the clinical and radiographic outcomes of both designs.
methodsWe reviewed 96 patients with 113 unstable distal radius fractures that were operated on with volar locking plates. The patients' mean age was 41 years. Fixed-angle volar locking plates were utilized in 65 fractures and variable-angle volar locking plates in 48 fractures through modified Henry approach or extended carpal tunnel approach. Full clinical and radiographic evaluation was done for all patients with a mean follow-up of 14 months.
resultsAll patients had acceptable clinical and radiographic parameters. The overall functional results (Mayo score, Quick Disability of Arm, Shoulder, and Hand (Q-DASH) score, Range of motion (ROM), and grip strength) were in favor of the variable-angle plate. The radiographic parameters were better with the variable-angle group. The variable-angle group recorded less operative time but more mean image intensifier exposure time. There were two cases of flexor tendon rupture with the fixed-angle group. Fixation with the fixed-angle system needed K-wire augmentation more than the variable-angle group. There was a positive correlation between hand dominance and the final score.
conclusionDistal radius volar locking plates yield satisfactory results comparable among different designs. In our series, the variable-angle system showed slightly better function and radiographic outcomes. Supplementary K-wires were needed more frequently with the fixed-angle system.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.