Evidence map›Paper›PMID 35689501›Full record

ArticleMedical physics2022

Performance evaluation of side-by-side optically coupled monolithic LYSO crystals.

Marta Freire, Sara Echegoyen, Andrea Gonzalez-Montoro, Filomeno Sanchez, Antonio J Gonzalez

Abstract read
In one paragraph

Article in Medical physics, 2022. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 5 papers.

0numbers the graph read from it
0cells of the map it votes in
5citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

5 citing papers in PubMed.

  1. Article
  2. Article
  3. Article
  4. Article
  5. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

5 authors.

Marta FreireInstituto de Instrumentación para Imagen Molecular (I3M), Centro Mixto CSIC - Universitat Politècnica de València, Valencia, Spain.
Sara EchegoyenInstituto de Instrumentación para Imagen Molecular (I3M), Centro Mixto CSIC - Universitat Politècnica de València, Valencia, Spain.
Andrea Gonzalez-MontoroInstituto de Instrumentación para Imagen Molecular (I3M), Centro Mixto CSIC - Universitat Politècnica de València, Valencia, Spain.
Filomeno SanchezInstituto de Instrumentación para Imagen Molecular (I3M), Centro Mixto CSIC - Universitat Politècnica de València, Valencia, Spain.
Antonio J GonzalezInstituto de Instrumentación para Imagen Molecular (I3M), Centro Mixto CSIC - Universitat Politècnica de València, Valencia, Spain.

Funding

EC | Emprego, Assuntos Sociais e Inclusão | European Social Fund (ESF) IDIFEDER/2021/004Foundation for the National Institutes of Health (FNIH) 1R01EB029450-01Ministerio de Ciencia, Innovación y Universidades (MCIU) PID2019-107790RB-C21
6 · The paper itself

Abstract

backgroundSignificant interest has been recently shown for using monolithic scintillation crystals in molecular imaging systems, such as positron emission tomography (PET) scanners. Monolithic-based PET scanners result in a lower cost and higher sensitivity, in contrast to systems based on the more conventional pixellated configuration. The monolithic design allows one to retrieve depth-of-interaction information of the impinging 511 keV photons without the need for additional hardware materials or complex positioning algorithms. However, the so-called edge-effect inherent to monolithic-based approaches worsens the detector performance toward the crystal borders due to the truncation of the light distribution, thus decreasing positioning accuracy. PURPOSE: The main goal of this work is to experimentally demonstrate the detector performance improvement when machine-learning artificial neural-network (NN) techniques are applied for positioning estimation in multiple monolithic scintillators optically coupled side-by-side.

methodsIn this work, we show the performance evaluation of two LYSO crystals of 33 × 25.4 × 10 mm

resultsAt the interface region of the detector, the SC method achieved spatial resolutions of 1.7 ± 0.3, 2.4 ± 0.3, and 2.6 ± 0.4 mm full-width at half-maximum (FWHM) for the Meltmount, grease, and standard configurations, respectively. These values improve to 1.0 ± 0.2, 1.2 ± 0.2, and 1.2 ± 0.3 mm FWHM when the NN algorithm was employed. Regarding energy performance, resolutions of 18 ± 2%, 20 ± 2%, and 23 ± 3% were obtained at the interface region of the detector for Meltmount, grease, and standard configurations, respectively.

conclusionsThe results suggest that optically coupling together scintillators with a high refractive index adhesive, in combination with an NN algorithm, reduces edge-effects and makes it possible to build scanners with almost no gaps in between detectors.

Indexed as

PhotonsPositron-Emission TomographyAlgorithmsMachine LearningNeural Networks, ComputerScintillation Countingmonolithic scintillatorneural networkoptical couplingPETposition estimation

Identifiers

PMID35689501
PMCPMC9545681

What OpenQuestion holds

Textmetadata
LicenceCC BY-NC-ND
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.