ArticleBMC pediatrics2022
Safety use of high frequency oscillatory ventilation in transport of newborn infants affected by severe respiratory failure: preliminary data in central Tuscany.
Article in BMC pediatrics, 2022. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 3 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
3 citing papers in PubMed.
- Contemporary Evidence on Interhospital Neonatal Transport as a Potentially Sepsis-Relevant Care Interval: A Scoping Review.Medicina (Kaunas, Lithuania) · 2026Article
- Safely developing respiratory care during emergency neonatal transport through systematic collection and analysis of detailed ventilator data.European journal of pediatrics · 2026Observational
- High-frequency oscillatory ventilation with or without volume guarantee during neonatal transport.Journal of perinatology : official journal of the California Perinatal Association · 2025Observational
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
15 authors.
Funding
No grant is acknowledged in the PubMed record.
Abstract
backgroundNeonatal Emergency Transport Services play a fundamental role in neonatal care. Stabilization before transport of newborns suffering from severe respiratory failure is often a challenging problem and some critically ill infants may benefit from High Frequency Oscillatory Ventilation (HFOV) as rescue treatment. In these cases, transition to conventional ventilation for transport may cause a deterioration in clinical conditions. HFOV during neonatal transport has been only exceptionally used, due to technical difficulties. Since May 2018, a new neonatal transport unit is available at the Neonatal Protected Transport Service of the Meyer University Hospital in Florence, equipped with a pulmonary ventilator capable of delivering HFOV. Therefore, we conducted an analysis on patients transferred in HFOV to Neonatal Intensive Care Unit (NICU), in order to evaluate the safety and feasibility of its use during neonatal transport.
methodsA retrospective analysis was performed reviewing medical records of the neonates transported by Meyer Children Hospital's Neonatal Transport Service between May 2018 and December 2020, and newborns treated with HFOV during ground neonatal transport were identified. Safety was assessed by the comparison of vital signs, hemogas-analysis values and pulmonary ventilator parameters, at the time of departure and upon arrival in NICU. The dose of inotropes, the main respiratory complications (air leak, dislocation or obstruction of the endotracheal tube, loss of chest vibrations) and the number of deaths and transfer failures were recorded.
resultsOut of the approximate 400 newborns transported during the analysis period, 9 were transported in HFOV. We did not find any statistically significant difference in vital parameters, hemogas-analytical values and pulmonary ventilator settings recorded before and after neonatal transport of the nine patients' parameters (p > 0,05). No patient required additional inotropes during transport. No transport-related deaths or significant complications occurred during transport.
conclusionsThe interest of our report is in the possibility of using HFOV during inter-hospital neonatal transfer. As far as our experience has shown, HFOV appears to be safe for the transportation of newborns with severe respiratory failure. Nevertheless, further larger, prospective and multicentre studies are needed to better evaluate the safety and efficacy of HFOV during neonatal transport.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.