ArticlePloS one2022

Effects of different stent wire mesh densities on hemodynamics in aneurysms of different sizes.

Shunsuke Masuda, Soichiro Fujimura, Hiroyuki Takao, Kohei Takeshita, Takashi Suzuki, Yuya Uchiyama, Kostadin Karagiozov, Toshihiro Ishibashi, Koji Fukudome, Makoto Yamamoto and 1 more

Open access · goldAbstract read
In one paragraph

Article in PloS one, 2022. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 5 papers.

0numbers the graph read from it
0cells of the map it votes in
5citing papers in PubMed
1.0field-weighted citation impact, top 23% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

5 citing papers in PubMed, 10 citations in OpenAlex.

  1. Swirling Flow Quantification in Helical Stents Using Ultrasound Velocimetry.Journal of endovascular therapy : an official journal of the International Society of Endovascular Specialists · 2026
    Article
  2. Article
  3. Hemodynamics in Cerebral Aneurysms and Parent Arteries With Incompletely Expanded Flow Diverter Stents.International journal for numerical methods in biomedical engineering · 2025
    Article
  4. Article
  5. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

11 authors at 2 institutions in 1 country.

Shunsuke MasudaDepartment of Innovation for Medical Information Technology, The Jikei University School of Medicine, Tokyo, Japan.
Soichiro FujimuraDepartment of Innovation for Medical Information Technology, The Jikei University School of Medicine, Tokyo, Japan.
Hiroyuki TakaoDepartment of Innovation for Medical Information Technology, The Jikei University School of Medicine, Tokyo, Japan.ORCID 0000-0002-9285-9642
Kohei TakeshitaDepartment of Innovation for Medical Information Technology, The Jikei University School of Medicine, Tokyo, Japan.
Takashi SuzukiDepartment of Innovation for Medical Information Technology, The Jikei University School of Medicine, Tokyo, Japan.ORCID 0000-0002-3575-393X
Yuya UchiyamaDepartment of Innovation for Medical Information Technology, The Jikei University School of Medicine, Tokyo, Japan.ORCID 0000-0003-3697-3616
Kostadin KaragiozovDepartment of Neurosurgery, The Jikei University School of Medicine, Tokyo, Japan.
Toshihiro IshibashiDepartment of Neurosurgery, The Jikei University School of Medicine, Tokyo, Japan.
Koji FukudomeDepartment of Mechanical Engineering, Tokyo University of Science, Tokyo, Japan.
Makoto YamamotoDepartment of Mechanical Engineering, Tokyo University of Science, Tokyo, Japan.ORCID 0000-0001-7844-331X
Yuichi MurayamaDepartment of Neurosurgery, The Jikei University School of Medicine, Tokyo, Japan.
Jikei University School of Medicine · JPTokyo University of Science · JP

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

backgroundIntracranial stents are used to treat aneurysms by diverting the blood flow from entering into the aneurysmal dome. Although delayed rupture is rare, clinical outcomes are extremely poor in such cases. Hemodynamics after stent deployment may be related to delayed rupture and a better understanding of the basic characteristics of pressure changes resulting from stent deployment is needed; therefore, this study investigated the relationships between hemodynamics in aneurysms of different sizes treated using stents of different wire mesh densities.

methodsUsing computational fluid dynamics analysis, parameters related to velocity, volume flow rate, pressure, and residual volume inside the aneurysm were evaluated in digital models of 5 basic aneurysms of differing sizes (Small, Medium, Medium-Large, Large, and Giant) and using 6 different types of stent (varying number of wires, stent pitch and wire mesh density) for each aneurysm.

resultsRegardless of the aneurysm size, the velocity inside the aneurysm and the volume flow rate into the aneurysm were observed to continuously decrease up to 89.2% and 78.1%, respectively, with increasing stent mesh density. In terms of pressure, for giant aneurysms, the pressure on the aneurysmal surface elevated to 10.3%, then decreased to 5.1% with increasing stent mesh density. However, in smaller aneurysms, this pressure continuously decreased with increasing stent mesh density. The flow-diverting effect of the stents was limited when a stent with low mesh density (under 20%) was used with a giant aneurysm.

conclusionsThe present results indicate that the selection of appropriate stents according to aneurysm size may contribute to reduced risks of hemodynamic alternations related to stent deployment, which could reduce the incidence of delayed rupture.

Indexed as

Intracranial AneurysmHemodynamicsHumansHydrodynamicsStentsSurgical Mesh

Identifiers

PMID35687558
PMCPMC9187070
OpenAlexW4281692419