Comparison of Ocular Morphological Parameters Related to Lens Position by Anterior Segment Optical Coherence Tomography and Ultrasound Biomicroscopy.

Zhiying Yu, Fenglei Wang, Fang Dong, Na Li, Dabo Wang, Ling Wang

Open access · goldAbstract read
In one paragraph

Article in International journal of clinical practice, 2022. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 5 papers.

0numbers the graph read from it
0cells of the map it votes in
5citing papers in PubMed
1.4field-weighted citation impact, top 21% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

5 citing papers in PubMed, 8 citations in OpenAlex.

  1. Article
  2. Article
  3. Article
  4. Article
  5. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

6 authors at 1 institution in 1 country.

Zhiying YuDepartment of Ophthalmology, The Affiliated Hospital of Qingdao University, Qingdao, China.ORCID https://orcid.org/0000-0001-9488-465X
Fenglei WangDepartment of Ophthalmology, The Affiliated Hospital of Qingdao University, Qingdao, China.ORCID https://orcid.org/0000-0002-9496-0525
Fang DongDepartment of Ophthalmology, The Affiliated Hospital of Qingdao University, Qingdao, China.ORCID https://orcid.org/0000-0002-7649-0347
Na LiDepartment of Ophthalmology, The Affiliated Hospital of Qingdao University, Qingdao, China.ORCID https://orcid.org/0000-0001-7054-8352
Dabo WangDepartment of Ophthalmology, The Affiliated Hospital of Qingdao University, Qingdao, China.ORCID https://orcid.org/0000-0002-7871-7330
Ling WangDepartment of Ophthalmology, The Affiliated Hospital of Qingdao University, Qingdao, China.ORCID https://orcid.org/0000-0003-1736-7880
Qingdao University · CN

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Objective: The objective is to compare parameters related to lens position measured using anterior segment optical coherence tomography (AS-OCT) and ultrasound biomicroscopy (UBM) in patients with senile cataract and perform a consistency analysis. Methods: This prospective study included 102 patients (102 eyes) scheduled for simple cataract surgery. Among the total patients, 44 were men, and 58 were women. AS-OCT (sitting) and UBM (lying) were used to measure the anterior chamber depth (ACD) in horizontal and vertical orientations and the iris-lens contact distance (ILCD) and iris-lens angle (ILA) in inferior, superior, nasal, and temporal quadrants. Paired-sample Results: The horizontal (2.499 ± 0.464 mm) and vertical (2.531 ± 0.463 mm) ACD measured using AS-OCT and the horizontal (2.556 ± 0.467 mm) and vertical (2.563 ± 0.479 mm) ACD measured using UBM were significantly different ( Conclusions: The correlation between AS-OCT and UBM in terms of measuring lens position-related parameters was good, but the agreement was unstable. The differences in measurement position (sitting and supine) and/or measurement methods (optics and ultrasound) may lead to variability in results.

Indexed as

CataractCataract ExtractionFemaleHumansMaleMicroscopy, AcousticProspective StudiesTomography, Optical Coherence

Identifiers

PMID35685518
PMCPMC9159221
OpenAlexW4221061081

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.