Evidence map›Paper›PMID 35684795›Full record

ArticleSensors (Basel, Switzerland)2022

A Procedure for Precise Determination and Compensation of Lead-Wire Resistance of a Two-Wire Resistance Temperature Detector.

Apinai Rerkratn, Supatsorn Prombut, Thawatchai Kamsri, Vanchai Riewruja, Wandee Petchmaneelumka

Open access · goldAbstract read
In one paragraph

Article in Sensors (Basel, Switzerland), 2022. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 4 papers.

0numbers the graph read from it
0cells of the map it votes in
4citing papers in PubMed
2.0field-weighted citation impact, top 13% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

4 citing papers in PubMed, 16 citations in OpenAlex.

  1. Article
  2. Article
  3. Article
  4. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

5 authors at 2 institutions in 1 country.

Apinai RerkratnSchool of Engineering, King Mongkut's Institute of Technology Ladkrabang, Bangkok 10520, Thailand.ORCID 0000-0003-2423-0102
Supatsorn PrombutSchool of Engineering, King Mongkut's Institute of Technology Ladkrabang, Bangkok 10520, Thailand.
Thawatchai KamsriThai Microeletronics Center (TMEC), Chachoengsao 24000, Thailand.
Vanchai RiewrujaSchool of Engineering, King Mongkut's Institute of Technology Ladkrabang, Bangkok 10520, Thailand.ORCID 0000-0002-4708-4665
Wandee PetchmaneelumkaSchool of Engineering, King Mongkut's Institute of Technology Ladkrabang, Bangkok 10520, Thailand.ORCID 0000-0002-0234-3475
King Mongkut's Institute of Technology Ladkrabang · THNational Electronics and Computer Technology Center · TH

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

A procedure for the precise determination and compensation of the lead-wire resistance of a resistance transducer is presented. The proposed technique is suitable for a two-wire resistance transducer, especially the resistance temperature detector (RTD). The proposed procedure provides a technique to compensate for the lead-wire resistance using a three-level pulse signal to excite the RTD via the long lead wire. In addition, the variation in the lead-wire resistance disturbed by the change in the ambient temperature can also be compensated by using the proposed technique. The determination of the lead-wire resistance from the proposed procedure requires a simple computation method performed by a digital signal processing unit. Therefore, the calculation of the RTD resistance and the lead-wire resistance can be achieved without the requirement of a high-speed digital signal processing unit. The proposed procedure is implemented on two platforms to confirm its effectiveness: the LabVIEW computer program and the microcontroller board. Experimental results show that the RTD resistance was accurately acquired, where the measured temperature varied from 0 °C to 300 °C and the lead-wire resistance varied from 0.2 Ω to 20 Ω, corresponding to the length of the 26 American wire gauge (AWG) lead wire from 1.5 m to 150 m. The average power dissipation to the RTD was very low and the self-heating of the RTD was minimized. The measurement error of the RTD resistance observed for pt100 was within ±0.98 Ω or ±0.27 °C when the lead wire of 30 m was placed in an environment with the ambient temperature varying from 30 °C to 70 °C. It is evident that the proposed procedure provided a performance that agreed with the theoretical expectation.

Indexed as

lead-wire compensationlead-wire resistanceremote measurementresistance temperature detectorthree-level pulse signalvoltage-to-current converter

Identifiers

PMID35684795
PMCPMC9185636
OpenAlexW4281783706

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.