Evidence map›Paper›PMID 35684617›Full record

ArticleSensors (Basel, Switzerland)2022

Wearable Blood Pressure Sensing Based on Transmission Coefficient Scattering for Microstrip Patch Antennas.

Mona K El Abbasi, Mervat Madi, Herbert F Jelinek, Karim Y Kabalan

Open access · goldAbstract read
In one paragraph

Article in Sensors (Basel, Switzerland), 2022. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 2 papers.

0numbers the graph read from it
0cells of the map it votes in
2citing papers in PubMed
1.1field-weighted citation impact, top 27% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

2 citing papers in PubMed, 13 citations in OpenAlex.

  1. Article
  2. Review
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

4 authors at 3 institutions in 2 countries.

Mona K El AbbasiElectrical and Computer Engineering Department, American University of Beirut, Beirut 1107 2020, Lebanon.
Mervat MadiElectrical and Electronics Engineering School Department, Amity University Dubai, Dubai P.O. Box 345019, United Arab Emirates.ORCID 0000-0003-3435-9890
Herbert F JelinekBiomedical Engineering Department and Health Innovation Engineering Center, Biotechnology Center, Khalifa University of Science and Technology, Abu Dhabi P.O. Box 127788, United Arab Emirates.
Karim Y KabalanElectrical and Computer Engineering Department, American University of Beirut, Beirut 1107 2020, Lebanon.
American University of Beirut · LBAmity University · AEKhalifa University of Science and Technology · AE

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Painless, cuffless and continuous blood pressure monitoring sensors provide a more dynamic measure of blood pressure for critical diagnosis or continuous monitoring of hypertensive patients compared to current cuff-based options. To this end, a novel flexible, wearable and miniaturized microstrip patch antenna topology is proposed to measure dynamic blood pressure (BP). The methodology was implemented on a simulated five-layer human tissue arm model created and designed in High-Frequency Simulation Software “HFSS”. The electrical properties of the five-layer human tissue were set at the frequency range (2−3) GHz to comply with clinical/engineering standards. The fabricated patch incorporated on a 0.4 mm epoxy substrate achieved consistency between the simulated and measured reflection coefficient results at flat and bent conditions over the frequency range of 2.3−2.6 GHz. Simulations for a 10 g average specific absorption rate (SAR) based on IEEE-Standard for a human arm at different input powers were also carried out. The safest input power was 50 mW with an acceptable SAR value of 3.89 W/Kg < 4W/Kg. This study also explored a novel method to obtain the pulse transit time (PTT) as an option to measure BP. Pulse transmit time is based on obtaining the time difference between the transmission coefficient scattering waveforms measured between the two pairs of metallic sensors underlying the assumption that brachial arterial geometries are dynamic. Consequently, the proposed model is validated by comparing it to the standard nonlinear Moens and Korteweg model over different artery thickness-radius ratios, showing excellent correlation between 0.76 ± 0.03 and 0.81 ± 0.03 with the systolic and diastolic BP results. The absolute risk of arterial blood pressure increased with the increase in brachial artery thickness-radius ratio. The results of both methods successfully demonstrate how the radius estimates, PTT and pulse wave velocity (PWV), along with electromagnetic (EM) antenna transmission propagation characteristics, can be used to estimate continuous BP non-invasively.

Indexed as

HypertensionWearable Electronic DevicesBlood PressureBlood Pressure DeterminationHumansPulse Wave Analysisblood pressurebrachial artery radius-to-tissue thickness ratiominiaturized microstrip patch antennaMoens-Korteweg equationspecific absorption ratetransmission coefficient scattering parameter

Identifiers

PMID35684617
PMCPMC9183053
OpenAlexW4281485600

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked