Evidence map›Paper›PMID 35684444›Full record

ArticleMolecules (Basel, Switzerland)2022

Portable Digital Linear Ion Trap Mass Spectrometer Based on Separate-Region Corona Discharge Ionization Source for On-Site Rapid Detection of Illegal Drugs.

Lingfeng Li, Tianyi Zhang, Deting Wang, Yunjing Zhang, Xingli He, Xiaozhi Wang, Peng Li

Open access · goldAbstract read
In one paragraph

Article in Molecules (Basel, Switzerland), 2022. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 2 papers.

0numbers the graph read from it
0cells of the map it votes in
2citing papers in PubMed
2.6field-weighted citation impact, top 9% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

2 citing papers in PubMed, 26 citations in OpenAlex.

  1. Article
  2. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

7 authors at 2 institutions in 1 country.

Lingfeng LiSchool of Electronic and Information Engineering, Soochow University, Suzhou 215006, China.
Tianyi ZhangSchool of Electronic and Information Engineering, Soochow University, Suzhou 215006, China.
Deting WangSchool of Electronic and Information Engineering, Soochow University, Suzhou 215006, China.
Yunjing ZhangSchool of Electronic and Information Engineering, Soochow University, Suzhou 215006, China.ORCID 0000-0002-4866-7053
Xingli HeSchool of Electronic and Information Engineering, Soochow University, Suzhou 215006, China.
Xiaozhi WangCollege of Information Science & Electronic Engineering, Zhejiang University, Hangzhou 310027, China.
Peng LiSchool of Electronic and Information Engineering, Soochow University, Suzhou 215006, China.ORCID 0000-0002-6423-2981
Soochow University · CNZhejiang University · CN

Funding

Chinese Postdoctoral Science Foundation No. 2020M671578Natural Science Foundation of Jiangsu Province No. BK20200876the National Natural Science Foundation of China No. 21904091 and 62001318
6 · The paper itself

Abstract

As narcotic control has become worse in the past decade and the death toll of drug abuse hits a record high, there is an increasing demand for on-site rapid detection of illegal drugs. This work developed a portable digital linear ion trap mass spectrometer based on separate-region corona discharge ionization source to meet this need. A separate design of discharge and reaction regions was adopted with filter air as both carrier gas for the analyte and protection of the corona discharge needle. The linear ion trap was driven by a digital waveform with a low voltage (±100 V) to cover a mass range of 50-500 Da with a unit resolution at a scan rate of 10,000 Da/s. Eighteen representative drugs were analyzed, demonstrating excellent qualitative analysis capability. Tandem mass spectrometry (MS/MS) was also performed by ion isolation and collision-induced dissociation (CID) with air as a buffer gas. With cocaine as an example, over two orders of magnitude dynamic range and 10 pg of detection limit were achieved. A single analysis time of less than 10 s was obtained by comparing the information of characteristic ions and product ions with the built-in database. Analysis of a real-world sample further validated the feasibility of the instrument, with the results benchmarked by GC-MS. The developed system has powerful analytical capability without using consumables including solvent and inert gas, meeting the requirements of on-site rapid detection applications.

Indexed as

CocaineIllicit DrugsGas Chromatography-Mass SpectrometryIonsTandem Mass SpectrometryCocaineIllicit DrugsIonscorona dischargedigital linear ion trapillegal drugson-site rapid detection

Identifiers

PMID35684444
PMCPMC9182377
OpenAlexW4281704055

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.