ArticleJournal of clinical medicine2022
Corneal Behavior during Tonometer Measurement during the Water Drinking Test in Eyes with XEN GelStent in Comparison to Non-Implanted Eyes.
Article in Journal of clinical medicine, 2022. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 2 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
2 citing papers in PubMed, 4 citations in OpenAlex.
- Article
- It Is All about Pressure.Journal of clinical medicine · 2022Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
5 authors at 2 institutions in 1 country.
Funding
Abstract
Biomechanics of the cornea have significant influences on the non-contact measurement of the intraocular pressure. The corneal behaviour during tonometry is a fundamental factor in estimating its value. The aim of the study was to analyse the behaviour of the cornea during tonometric measurement with the forced change in intraocular pressure during the water drinking test. Ocular Response Analyser (Reichert) was used to the measurement. Besides four basic parameters connected with intraocular pressure (IOPg, IOPcc) and biomechanics (corneal hysteresis CH and corneal resistance factor (CRF), other parameters representing the behaviour of the cornea during a puff of air were analysed. There were 47 eyes included in the study, including 27 eyes with a XEN GelStent implanted and 20 without it. The eyes of people with monocular implementation were the reference group. The values of analysed parameters were compared before and after 10, 25, 40, and 55 min after drinking the water. The intraocular pressure increased by 2.4 mmHg (p < 0.05) for eyes with a XEN stent and 2.2 mmHg for eyes without a stent (p < 0.05) in the tenth minute after drinking of water. This change caused a decreasing of corneal hysteresis (p < 0.05) without significant changes in the corneal resistance factor (p > 0.05). Corneal hysteresis changed similarly in the reference group and the group with a XEN GelStent. The analysis of additional parameters showed a difference in the behaviour of the cornea in eyes with a XEN GelStent in comparison to the corneas of eyes without a stent. This was particularly visible in the analysis of the cornea’s behaviour during the second applanation, when the cornea returns to its baseline state after deformation caused by air puff tonometry.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials