Evidence map›Paper›PMID 35683151›Full record

ArticleMaterials (Basel, Switzerland)2022

Accuracy of 3D Tooth Movements in the Fabrication of Manual Setup Models for Aligner Therapy.

Hisham Sabbagh, Sebastian Marcus Heger, Thomas Stocker, Uwe Baumert, Andrea Wichelhaus, Lea Hoffmann

Abstract read
In one paragraph

Article in Materials (Basel, Switzerland), 2022. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 7 papers.

0numbers the graph read from it
0cells of the map it votes in
7citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

7 citing papers in PubMed.

  1. Article
  2. Review
  3. Review
  4. Article
  5. Article
  6. Article
  7. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

6 authors.

Hisham SabbaghDepartment of Orthodontics and Dentofacial Orthopedics, University Hospital, LMU Munich, Goethestrasse 70, 80336 Munich, Germany.ORCID 0000-0002-9535-6901
Sebastian Marcus HegerPrivate Practice "Dr. Heger", Fürther Strasse 2, 90429 Nürnberg, Germany.
Thomas StockerDepartment of Orthodontics and Dentofacial Orthopedics, University Hospital, LMU Munich, Goethestrasse 70, 80336 Munich, Germany.
Uwe BaumertDepartment of Orthodontics and Dentofacial Orthopedics, University Hospital, LMU Munich, Goethestrasse 70, 80336 Munich, Germany.ORCID 0000-0002-4693-6969
Andrea WichelhausDepartment of Orthodontics and Dentofacial Orthopedics, University Hospital, LMU Munich, Goethestrasse 70, 80336 Munich, Germany.
Lea HoffmannDepartment of Orthodontics and Dentofacial Orthopedics, University Hospital, LMU Munich, Goethestrasse 70, 80336 Munich, Germany.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Background: The clinical outcome of aligner therapy is closely related to the precision of its setup, which can be manually or digitally fabricated. The aim of the study is to investigate the suitability of manual setups made for aligner therapy in terms of the precision of tooth movements. Methods: Six dental technicians were instructed to adjust each of eleven duplicate plaster casts of a patient models as follows: a 1 mm pure vestibular translation of tooth 11 and a 15° pure mesial rotation of tooth 23. The processed setup models were 3D scanned and matched with the reference model. The one-sample Wilcoxon signed-rank test (p < 0.05) was used for evaluation. Results: The overall precision of the translational movement covers a wide range of values from 0.25 to 2.26 mm (median: 1.09 mm). The target value for the rotation of tooth 23 was achieved with a median rotation of 9.76° in the apical-occlusal direction. Unwanted movements in the other planes also accompanied the rotation. Conclusions: A manual setup can only be fabricated with limited precision. Besides the very high variability between technicians, additional unwanted movements in other spatial planes occurred. Manually fabricated setups should not be favored for aligner therapy due to limited precision.

Indexed as

alignerclear alignerdental castsorthodontic appliance

Identifiers

PMID35683151
PMCPMC9182206

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.