Evidence map›Paper›PMID 35683075›Full record

ArticleMaterials (Basel, Switzerland)2022

Heat Treatments of Metastable β Titanium Alloy Ti-24Nb-4Zr-8Sn Processed by Laser Powder Bed Fusion.

Maxwell Hein, Nelson Filipe Lopes Dias, Sudipta Pramanik, Dominic Stangier, Kay-Peter Hoyer, Wolfgang Tillmann, Mirko Schaper

Abstract read
In one paragraph

Article in Materials (Basel, Switzerland), 2022. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 7 papers.

0numbers the graph read from it
0cells of the map it votes in
7citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

7 citing papers in PubMed.

  1. Article
  2. Article
  3. Review
  4. Article
  5. Review
  6. Review
  7. Emerging Materials for Additive Manufacturing.Materials (Basel, Switzerland) · 2022
    Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

7 authors.

Maxwell HeinChair of Materials Science (LWK), Paderborn University, Warburger Str. 100, 33098 Paderborn, Germany.ORCID 0000-0002-3732-2236
Nelson Filipe Lopes DiasInstitute of Materials Engineering (LWT), TU Dortmund University, Leonhard-Euler-Str. 2, 44227 Dortmund, Germany.ORCID 0000-0002-0541-4697
Sudipta PramanikChair of Materials Science (LWK), Paderborn University, Warburger Str. 100, 33098 Paderborn, Germany.ORCID 0000-0002-1901-6593
Dominic StangierInstitute of Materials Engineering (LWT), TU Dortmund University, Leonhard-Euler-Str. 2, 44227 Dortmund, Germany.
Kay-Peter HoyerChair of Materials Science (LWK), Paderborn University, Warburger Str. 100, 33098 Paderborn, Germany.ORCID 0000-0001-9582-1503
Wolfgang TillmannInstitute of Materials Engineering (LWT), TU Dortmund University, Leonhard-Euler-Str. 2, 44227 Dortmund, Germany.
Mirko SchaperChair of Materials Science (LWK), Paderborn University, Warburger Str. 100, 33098 Paderborn, Germany.

Funding

Deutsche Forschungsgemeinschaft SCHA 1484/45-1Deutsche Forschungsgemeinschaft TI 343/167-1
6 · The paper itself

Abstract

Titanium alloys, especially β alloys, are favorable as implant materials due to their promising combination of low Young's modulus, high strength, corrosion resistance, and biocompatibility. In particular, the low Young's moduli reduce the risk of stress shielding and implant loosening. The processing of Ti-24Nb-4Zr-8Sn through laser powder bed fusion is presented. The specimens were heat-treated, and the microstructure was investigated using X-ray diffraction, scanning electron microscopy, and transmission electron microscopy. The mechanical properties were determined by hardness and tensile tests. The microstructures reveal a mainly β microstructure with α″ formation for high cooling rates and α precipitates after moderate cooling rates or aging. The as-built and α″ phase containing conditions exhibit a hardness around 225 HV5, yield strengths (YS) from 340 to 490 MPa, ultimate tensile strengths (UTS) around 706 MPa, fracture elongations around 20%, and Young's moduli about 50 GPa. The α precipitates containing conditions reveal a hardness around 297 HV5, YS around 812 MPa, UTS from 871 to 931 MPa, fracture elongations around 12%, and Young's moduli about 75 GPa. Ti-24Nb-4Zr-8Sn exhibits, depending on the heat treatment, promising properties regarding the material behavior and the opportunity to tailor the mechanical performance as a low modulus, high strength implant material.

Indexed as

biomedical engineeringlaser powder bed fusionmechanical propertiesmicrostructureTi-24Nb-4Zr-8Sntitanium alloyX-ray diffraction

Identifiers

PMID35683075
PMCPMC9181302

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.