Evidence map›Paper›PMID 35679231›Full record

ArticlePloS one2022

The placement of foot-mounted IMU sensors does affect the accuracy of spatial parameters during regular walking.

Arne Küderle, Nils Roth, Jovana Zlatanovic, Markus Zrenner, Bjoern Eskofier, Felix Kluge

Open access · goldAbstract read
In one paragraph

Article in PloS one, 2022. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 20 papers, 2 of them syntheses that pooled it.

0numbers the graph read from it
0cells of the map it votes in
20citing papers in PubMed, 2 pooled it
11.3field-weighted citation impact, top 1% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

20 citing papers in PubMed, 2 syntheses or guidelines pooled it, 28 citations in OpenAlex.

  1. Pooled it
  2. Pooled it
  3. Article
  4. Article
  5. Article
  6. Review
  7. Article
  8. Article
  9. Article
  10. Article
  11. Article
  12. Article
  13. Review
  14. Article
  15. Article
  16. Article
  17. Article
  18. Gaitmap-An Open Ecosystem for IMU-Based Human Gait Analysis and Algorithm Benchmarking.IEEE open journal of engineering in medicine and biology · 2024
    Article
  19. Article
  20. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

6 authors at 1 institution in 1 country.

Arne KüderleMachine Learning and Data Analytics Lab, Friedrich-Alexander-Universität Erlangen-Nürnberg, Erlangen, Germany.ORCID 0000-0002-5686-281X
Nils RothMachine Learning and Data Analytics Lab, Friedrich-Alexander-Universität Erlangen-Nürnberg, Erlangen, Germany.
Jovana ZlatanovicMachine Learning and Data Analytics Lab, Friedrich-Alexander-Universität Erlangen-Nürnberg, Erlangen, Germany.
Markus ZrennerMachine Learning and Data Analytics Lab, Friedrich-Alexander-Universität Erlangen-Nürnberg, Erlangen, Germany.
Bjoern EskofierMachine Learning and Data Analytics Lab, Friedrich-Alexander-Universität Erlangen-Nürnberg, Erlangen, Germany.
Felix KlugeMachine Learning and Data Analytics Lab, Friedrich-Alexander-Universität Erlangen-Nürnberg, Erlangen, Germany.
Friedrich-Alexander-Universität Erlangen-Nürnberg · DE

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Gait analysis using foot-worn inertial measurement units has proven to be a reliable tool to diagnose and monitor many neurological and musculoskeletal indications. However, only few studies have investigated the robustness of such systems to changes in the sensor attachment and no consensus for suitable sensor positions exists in the research community. Specifically for unsupervised real-world measurements, understanding how the reliability of the monitoring system changes when the sensor is attached differently is from high importance. In these scenarios, placement variations are expected because of user error or personal preferences. In this manuscript, we present the largest study to date comparing different sensor positions and attachments. We recorded 9000 strides with motion-capture reference from 14 healthy participants with six synchronized sensors attached at each foot. Spatial gait parameters were calculated using a double-integration method and compared to the reference system. The results indicate that relevant differences in the accuracy of the stride length exists between the sensor positions. While the average error over multiple strides is comparable, single stride errors and variability parameters differ greatly. We further present a physics model and an analysis of the raw sensor data to understand the origin of the observed differences. This analysis indicates that a variety of attachment parameters can influence the systems' performance. While this is only the starting point to understand and mitigate these types of errors, we conclude that sensor systems and algorithms must be reevaluated when the sensor position or attachment changes.

Indexed as

FootWalkingAlgorithmsGaitGait AnalysisHumansReproducibility of Results

Identifiers

PMID35679231
PMCPMC9182246
OpenAlexW4281688779

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.