Evidence map›Paper›PMID 35678760›Full record

ArticleLangmuir : the ACS journal of surfaces and colloids2022

Surface Area and Local Curvature: Why Roughness Improves the Bioactivity of Neural Implants.

Ruikang Ding, Nathaniel C Miller, Kevin M Woeppel, Xinyan T Cui, Tevis D B Jacobs

Abstract read
In one paragraph

Article in Langmuir : the ACS journal of surfaces and colloids, 2022. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 7 papers.

0numbers the graph read from it
0cells of the map it votes in
7citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

7 citing papers in PubMed.

  1. Article
  2. Review
  3. Review
  4. Article
  5. Article
  6. Article
  7. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

5 authors.

Ruikang DingMechanical Engineering & Materials Science, University of Pittsburgh, 3700 O'Hara St., Benedum Hall Room 636, Pittsburgh, Pennsylvania 15261, United States.
Nathaniel C MillerMechanical Engineering & Materials Science, University of Pittsburgh, 3700 O'Hara St., Benedum Hall Room 636, Pittsburgh, Pennsylvania 15261, United States.
Kevin M WoeppelBioengineering, University of Pittsburgh, 5057 Biomedical Science Tower 3, 3501 Fifth Ave, Pittsburgh, Pennsylvania 15260, United States.
Xinyan T CuiBioengineering, University of Pittsburgh, 5057 Biomedical Science Tower 3, 3501 Fifth Ave, Pittsburgh, Pennsylvania 15260, United States.ORCID 0000-0002-0470-2005
Tevis D B JacobsMechanical Engineering & Materials Science, University of Pittsburgh, 3700 O'Hara St., Benedum Hall Room 636, Pittsburgh, Pennsylvania 15261, United States.ORCID 0000-0001-8576-914X

Funding

Efficiency and Safety of Microstimulation Via Different Electrode MaterialsR01NS110564 · NINDS · UNIVERSITY OF PITTSBURGH AT PITTSBURGH · PI CUI, XINYAN TRACY · 2019 to 2024
$3.1M
Inhibition of Neural Electrode-mediated Inflammation and Neuronal Cell DeathR01NS089688 · NINDS · UNIVERSITY OF PITTSBURGH AT PITTSBURGH · PI CUI, XINYAN TRACY · 2015 to 2019
$3.1M
Optimization and Delivery of Bioactive Coating for High Yield and Stable Neural RecordingU01NS113279 · NINDS · UNIVERSITY OF PITTSBURGH AT PITTSBURGH · PI CUI, XINYAN TRACY · 2019 to 2022
$2.4M
NINDS NIH HHS R01 NS089688NINDS NIH HHS R01 NS110564NINDS NIH HHS U01 NS113279
6 · The paper itself

Abstract

While roughening the surface of neural implants has been shown to significantly improve their performance, the mechanism for this improvement is not understood, preventing systematic optimization of surfaces. Specifically, prior work has shown that the cellular response to a surface can be significantly enhanced by coating the implant surface with inorganic nanoparticles and neuroadhesion protein L1, and this improvement occurs even when the surface chemistry is identical between the nanoparticle-coated and uncoated electrodes, suggesting the critical importance of surface topography. Here, we use transmission electron microscopy to characterize the topography of bare and nanoparticle-coated implants across 7 orders of magnitude in size, from the device scale to the atomic scale. The results reveal multiscale roughness, which cannot be adequately described using conventional roughness parameters. Indeed, the topography is nearly identical between the two samples at the smallest scales and also at the largest scales but vastly different in the intermediate scales, especially in the range of 5-100 nm. Using a multiscale topography analysis, we show that the coating causes a 76% increase in the available surface area for contact and an order-of-magnitude increase in local surface curvature at characteristic sizes corresponding to specific biological structures. These are correlated with a 75% increase in bound proteins on the surface and a 134% increase in neurite outgrowth. The present investigation presents a framework for analyzing the scale-dependent topography of medical device-relevant surfaces, and suggests the most critical size scales that determine the biological response to implanted materials.

Indexed as

NanoparticlesTitaniumCoated Materials, BiocompatibleSurface PropertiesCoated Materials, BiocompatibleTitanium

Identifiers

PMID35678760
PMCPMC10080668

What OpenQuestion holds

Textmetadata
LicenceTDM
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.