ArticleProceedings of SPIE--the International Society for Optical Engineering
Improving coronary artery imaging in single source CT with cardiac motion correction using attention and spatial transformer based neural networks.
Article in Proceedings of SPIE--the International Society for Optical Engineering. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
1 citing paper in PubMed, 5 citations in OpenAlex.
- Deep Learning-Based Cardiac CT Coronary Motion Correction Method with Temporal Weight Adjustment: Clinical Data Evaluation.Journal of imaging informatics in medicine · 2026Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
6 authors at 2 institutions in 1 country.
Funding
Abstract
Motion artifact is a major challenge in cardiac CT which hampers accurate delineation of key anatomic (e.g. coronary lumen) and pathological features (e.g. stenosis). Conventional motion correction techniques are limited on patients with high / irregular heart rate, due to simplified modeling of CT systems and cardiac motion. Emerging deep learning based cardiac motion correction techniques have demonstrated the potential of further quality improvement. Yet, many methods require CT projection data or advanced motion simulation tools that are not readily available. We aim to develop an image-domain motion-correction method, using convolutional neural network (CNN) integrated with customized attention and spatial transformer techniques. Forty cardiac CT exams acquired from a clinical dual-source CT system were retrospectively collected to generate training (n=26) and testing (n=14) sets. Dual-source data uniquely allow image reconstruction with different temporal resolutions from the same patient scan. Slow temporal resolution (140ms; equivalent to single-source CT (SSCT) half scan) and fast temporal resolution (75ms; dual source) images were reconstructed to generate paired samples of motion-corrupted and reference images. The combinations of 2 training-inference strategies and 3 CNNs were evaluated: strategy #1 - whole-heart images in training / inference; strategy #2 - vessel patches in training / inference; CNN #1 - attention only; CNN #2 - spatial-transformer (STN) only; CNN #3 - attention & STN synergy. Testing data showed that CNN #3 with strategy #2 provided relatively better performance: improving vessel delineation, increasing structural similarity index from 0.85 to 0.91, and reducing mean CT number error of lumen by 71.0%. Our method could improve the image quality in cardiac exams with SSCT.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.