Evidence map›Paper›PMID 35674145›Full record

ArticleACS biomaterials science & engineering2022

Microfluidic Systems For Manufacturing of Microparticle-Based Drug-Delivery Systems: Design, Construction, and Operation.

Nihan Yonet-Tanyeri, Maher Amer, Stephen C Balmert, Emrullah Korkmaz, Louis D Falo, Steven R Little

Abstract read
In one paragraph

Article in ACS biomaterials science & engineering, 2022. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 9 papers.

0numbers the graph read from it
0cells of the map it votes in
9citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

9 citing papers in PubMed.

  1. Article
  2. Article
  3. Article
  4. PLGA-based long-acting injectable (LAI) formulations.Journal of controlled release : official journal of the Controlled Release Society · 2025
    Review
  5. Article
  6. Article
  7. Article
  8. Article
  9. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

6 authors.

Nihan Yonet-TanyeriDepartment of Chemical Engineering, University of Pittsburgh, 3700 O'Hara Street, 940 Benedum Hall, Pittsburgh, Pennsylvania 15261, United States.
Maher AmerDepartment of Dermatology, University of Pittsburgh School of Medicine, 200 Lothrop Street, W1150 Biomedical Science Tower, Pittsburgh, Pennsylvania 15213, United States.
Stephen C BalmertDepartment of Dermatology, University of Pittsburgh School of Medicine, 200 Lothrop Street, W1150 Biomedical Science Tower, Pittsburgh, Pennsylvania 15213, United States.
Emrullah KorkmazDepartment of Dermatology, University of Pittsburgh School of Medicine, 200 Lothrop Street, W1150 Biomedical Science Tower, Pittsburgh, Pennsylvania 15213, United States.
Louis D FaloDepartment of Dermatology, University of Pittsburgh School of Medicine, 200 Lothrop Street, W1150 Biomedical Science Tower, Pittsburgh, Pennsylvania 15213, United States.
Steven R LittleDepartment of Chemical Engineering, University of Pittsburgh, 3700 O'Hara Street, 940 Benedum Hall, Pittsburgh, Pennsylvania 15261, United States.ORCID 0000-0002-7000-3931

Funding

Engineering the Skin Immune System to Induce Systemic Immune ResponsesR01AR079233 · NIAMS · UNIVERSITY OF PITTSBURGH AT PITTSBURGH · PI FALO, LOUIS D · 2021 to 2025
$3.3M
Engineering the Skin Microenvironment to Promote Allergen ToleranceR01AR074285 · NIAMS · UNIVERSITY OF PITTSBURGH AT PITTSBURGH · PI FALO, LOUIS D, LITTLE, STEVEN R · 2018 to 2023
$3.0M
NIAMS NIH HHS R01 AR074285NIAMS NIH HHS R01 AR079233
6 · The paper itself

Abstract

Particles synthesized from biodegradable polymers hold great potential as controlled drug delivery systems. Continuous flow platforms based on microfluidics offer attractive advantages over conventional batch-emulsification techniques for the scalable fabrication of drug-loaded particles with controlled physicochemical properties. However, widespread utilization of microfluidic technologies for the manufacturing of drug-loaded particles has been hindered largely by the lack of practical guidelines toward cost-effective development and reliable operation of microfluidic systems. Here, we present a framework for rational design and construction of microfluidic systems using commercially available components for high-throughput production of uniform biodegradable particles encapsulating drugs. We also demonstrate successful implementation of this framework to devise a robust microfluidic system that is capable of producing drug-carrying particles with desired characteristics. The guidelines provided in this study will likely help broaden the applicability of microfluidic technologies for the synthesis of high-quality, drug-loaded biodegradable particles.

Indexed as

Drug Delivery SystemsMicrofluidicsbiodegradable microparticlesdroplet generatorsdrug carriersmicrofluidicsPLGA

Identifiers

PMID35674145
PMCPMC10368402

What OpenQuestion holds

Textmetadata
LicenceTDM
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.