ArticleClinical ophthalmology (Auckland, N.Z.)2022
Comparison of Barrett Toric Calculations Using Measured and Predicted Posterior Corneal Astigmatism in Cataract Surgery Patients.
Article in Clinical ophthalmology (Auckland, N.Z.), 2022. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 5 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
5 citing papers in PubMed, 12 citations in OpenAlex.
- Measured corneal astigmatism vs. predicted refractive astigmatism in determining astigmatism correction in cataract patients with low astigmatism.Graefe's archive for clinical and experimental ophthalmology = Albrecht von Graefes Archiv fur klinische und experimentelle Ophthalmologie · 2026Article
- Comparative evaluation of several toric intraocular lens calculators for predicting postoperative refractive astigmatism in cataract surgery: a real-world study.BMC ophthalmology · 2025Article
- Prevalence of corneal astigmatism in patients undergoing cataract surgery in India.Bioinformation · 2025Article
- Assessment of the refractive outcomes of patients with regular corneal astigmatism implanted with high-power toric intraocular lenses.Graefe's archive for clinical and experimental ophthalmology = Albrecht von Graefes Archiv fur klinische und experimentelle Ophthalmologie · 2024Article
- Accuracy of Toric Intraocular Lens Calculators with Predicted and Measured Posterior Corneal Astigmatism Across Different Types of Astigmatism.Ophthalmology and therapy · 2024Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
5 authors at 1 institution in 1 country.
Funding
No grant is acknowledged in the PubMed record.
Abstract
Aim: To compare residual astigmatism prediction errors across Barrett toric calculations using predicted posterior corneal astigmatism (PCA) and PCA measured using the IOL Master 700 with total keratometry (IOLM). Methods: A retrospective cohort study was undertaken on patients with corneal astigmatism and no other ocular comorbidities that underwent uneventful refractive femtosecond laser-assisted cataract surgery with toric IOL implantation between May 2019 and November 2019. Toric calculations were performed using the Barrett toric calculator and the following values: predicted PCA with anterior corneal measurements from Pentacam, IOLM standard keratometry (SK), OPD scan, and median measurements from these devices; predicted PCA with IOLM total keratometry (TK); and measured PCA with IOLM SK or IOLM TK. Residual astigmatism prediction error was calculated for each device and method of calculation at postoperative month 1 and 3 using the astigmatism double angle plot tool. Results: A total of 24 eyes, 10 with-the-rule (WTR), 10 against-the-rule (ATR) and 4 oblique astigmatism, from 24 patients were included in this study. PCA ranged from 0.00 to 0.67 D with a mean of 0.24 ± 0.15 D in all eyes. PCA was significantly greater in WTR eyes (0.32 D) compared to ATR eyes (0.16 D; p < 0.05). In ATR eyes, calculations made using IOLM SK and measured PCA had significantly lower total corneal astigmatism and toric IOL cylinder power compared to calculations made using Pentacam and IOLM TK (p < 0.05). No significant difference in mean absolute or centroid residual astigmatism prediction error was observed across devices or calculation methods. The percentage of eyes with absolute astigmatism prediction errors ≤0.5 D was not significantly different across groups. Conclusion: Barrett toric calculations using predicted PCA and PCA measured using IOLM produced comparable residual astigmatism prediction errors. The incorporation of median measurements did not significantly impact calculation accuracy.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.