ArticleASAIO journal (American Society for Artificial Internal Organs : 1992)2022
Association of Ventilator Settings With Mortality in Pediatric Patients Treated With Extracorporeal Life Support for Respiratory Failure.
Article in ASAIO journal (American Society for Artificial Internal Organs : 1992), 2022. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 6 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
6 citing papers in PubMed, 13 citations in OpenAlex.
- Liquid Lung Rest During Extracorporeal Life Support in a Neonatal Porcine Model of Acute Lung Injury.ASAIO journal (American Society for Artificial Internal Organs : 1992) · 2026Article
- Positive end-expiratory pressure in pediatric acute respiratory distress syndrome: a narrative review.Translational pediatrics · 2026Review
- Cost-effectiveness of the timing of respiratory extracorporeal membrane oxygenation initiation in pediatric patients.Revista paulista de pediatria : orgao oficial da Sociedade de Pediatria de Sao Paulo · 2026Article
- Association between mechanical ventilation parameters and mortality in children with respiratory failure on ECMO: a systematic review and meta-analysis.Frontiers in pediatrics · 2024Review
- Association between pediatric intensive care mortality and mechanical ventilation settings during extracorporeal membrane oxygenation for pediatric acute respiratory distress syndrome.European journal of pediatrics · 2023Observational
- Extracorporeal Membrane Oxygenation.Respiratory care · 2023Review
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
7 authors at 3 institutions in 2 countries.
Funding
Abstract
Extracorporeal life support (ECLS) is a treatment for acute respiratory failure that can provide extracorporeal gas exchange, allowing lung rest. However, while most patients remain mechanically ventilated during ECLS, there is a paucity of evidence to guide the choice of ventilator settings. We studied the associations between ventilator settings 24 hours after ECLS initiation and mortality in pediatric patients using a retrospective analysis of data from the Extracorporeal Life Support Organization Registry. 3497 patients, 29 days to 18 years of age, treated with ECLS for respiratory failure between 2015 and 2021, were included for analysis. 93.3% of patients on ECLS were ventilated with conventional mechanical ventilation. Common settings included positive end-expiratory pressure (PEEP) of 10 cm H 2 O (45.7%), delta pressure (ΔP) of 10 cm H 2 O (28.3%), rate of 10-14 breaths per minute (55.9%), and fraction of inspired oxygen (FiO 2 ) of 0.31-0.4 (30.3%). In a multivariate model, PEEP >10 cm H 2 O ( versus PEEP < 8 cm H 2 O, odds ratio [OR]: 1.53, 95% CI: 1.20-1.96) and FiO 2 ≥0.45 ( versus FiO 2 < 0.4; 0.45 ≤ FiO 2 < 0.6, OR: 1.31, 95% CI: 1.03-1.67 and FiO 2 ≥ 0.6, OR: 2.30; 95% CI: 1.81-2.93) were associated with higher odds of mortality. In a secondary analysis of survivors, PEEP 8-10 cm H 2 O was associated with shorter ECLS run times ( versus PEEP < 8 cm H 2 O, coefficient: -1.64, 95% CI: -3.17 to -0.11), as was ΔP >16 cm H 2 O ( versus ΔP < 10 cm H 2 O, coefficient: -2.72, 95% CI: -4.30 to -1.15). Our results identified several categories of ventilator settings as associated with mortality or ECLS run-time. Further studies are necessary to understand whether these results represent a causal relationship.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.