Evidence map›Paper›PMID 35671368›Full record

ArticleBiomedical instrumentation & technology2022

Signaling Patient Oxygen Desaturation with Enhanced Pulse Oximetry Tones.

Penelope M Sanderson, Robert G Loeb, Helen Liley, David Liu, Estrella Paterson, Kelly Hinckfuss, Jelena Zestic

Open access · greenAbstract read
In one paragraph

Article in Biomedical instrumentation & technology, 2022. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
0.4field-weighted citation impact, top 38% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed, 2 citations in OpenAlex.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

7 authors at 4 institutions in 2 countries.

Penelope M SandersonPenelope M. Sanderson, PhD, is professor of cognitive engineering and human factors in the Schools of Psychology, Clinical Medicine, and Information Technology and Electrical Engineering at The University of Queensland in Queensland, Australia. Email: p.sanderson@uq.edu.au.
Robert G LoebRobert G. Loeb, MD, is an honorary professor in the School of Psychology at The University of Queensland in Queensland, Australia, and an emeritus clinical professor at University of Florida-Gainesville.
Helen LileyHelen Liley, MBCh, FRACP, is a senior staff specialist at Mater Mothers' Hospital and a professor in the Faculty of Medicine at The University of Queensland in Queensland, Australia.
David LiuDavid Liu, MBBS, PhD, is an anaesthetics registrar at Sunshine Coast University Hospital in Queensland, Australia, and a senior lecturer in the Faculty of Medicine at The University of Queensland in Queensland, Australia.
Estrella PatersonEstrella Paterson, PhD, is a postdoctoral fellow in the School of Psychology at The University of Queensland in Queensland, Australia.
Kelly HinckfussKelly Hinckfuss, MPhil, is a clinical masters student in the School of Psychology at The University of Queensland in Queensland, Australia.
Jelena ZesticJelena Zestic, PhD, is a human systems engineer at Boeing Research and Technology in Brisbane, Australia.
University of Queensland · AUBoeing (Australia) · AUMater Mothers' Hospital · AUUniversity of Florida · US

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Manufacturers could improve the pulse tones emitted by pulse oximeters to support more accurate identification of a patient's peripheral oxygen saturation (SpO2) range. In this article, we outline the strengths and limitations of the variable-pitch tone that represents SpO2 of each detected pulse, and we argue that enhancements to the tone to demarcate clinically relevant ranges are feasible and desirable. The variable-pitch tone is an appreciated and trusted feature of the pulse oximeter's user interface. However, studies show that it supports relative judgments of SpO2 trends over time and is less effective at supporting absolute judgments about the SpO2 number or conveying when SpO2 moves into clinically important ranges. We outline recent studies that tested whether acoustic enhancements to the current tone could convey clinically important ranges more directly, without necessarily using auditory alarms. The studies cover the use of enhanced variable-pitch pulse oximeter tones for neonatal and adult use. Compared with current tones, the characteristics of the enhanced tones represent improvements that are both clinically relevant and statistically significant. We outline the benefits of enhanced tones, as well as discuss constraints of which developers of enhanced tones should be aware if enhancements are to be successful.

Indexed as

OximetryOxygenAdultHumansInfant, NewbornOxygen

Identifiers

PMID35671368
PMCPMC9767428
OpenAlexW4281626571

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.