Evidence map›Paper›PMID 35668428›Full record

ArticleBMC musculoskeletal disorders2022

Oblique-ilioischial plate technique: a novel method for acetabular fractures involving low posterior column.

Zhong Chen, Zhao-Xiang Wu, Ge Chen, Yi Ou, Hong-Jie Wen

Open access · goldAbstract readMulticenter Study
In one paragraph

Article in BMC musculoskeletal disorders, 2022. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 3 papers, 1 of them a synthesis that pooled it.

0numbers the graph read from it
0cells of the map it votes in
3citing papers in PubMed, 1 pooled it
0.7field-weighted citation impact, top 32% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

3 citing papers in PubMed, 1 synthesis or guideline pooled it, 3 citations in OpenAlex.

  1. Pooled it
  2. Article
  3. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

5 authors at 2 institutions in 1 country.

Zhong ChenDepartment of Orthopaedic and Trauma, The Second People's Hospital of Yunnan Province, Kunming, China.
Zhao-Xiang WuDepartment of Orthopaedic and Trauma, The Second People's Hospital of Yunnan Province, Kunming, China.
Ge ChenDepartment of Orthopaedic and Trauma, The Second People's Hospital of Yunnan Province, Kunming, China.
Yi OuDepartment of Orthopaedic and Trauma, The Second People's Hospital of Yunnan Province, Kunming, China. 273910478@qq.com.
Hong-Jie WenDepartment of Orthopaedic and Trauma, The Second People's Hospital of Yunnan Province, Kunming, China. whj20000@163.com.
Second People's Hospital of Yunnan Province · CNYunnan University · CN

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

backgroundComplex acetabular fractures involving the anterior and posterior columns are an intractable clinical challenge. The study investigated the safety and efficacy of oblique-ilioischial plate technique for acetabular fractures involving low posterior column.

methodsA retrospective analysis of 18 patients operated with the oblique-ilioischial plate technique by the modified Stoppa approach (or combined with iliac fossa approach) between August 2016 and July 2021 for low posterior column acetabular fractures was conducted. The anterior column was fixed with a reconstructed plate from the iliac wing along the iliopectineal line to the pubis. The low posterior column was fixed with the novel oblique-ilioischial plate running from the ilium to the ischial ramus. Operative time, intraoperative blood loss, reduction quality, and postoperative hip function were recorded.

resultsOut of the 18 patients, 10 were male and 8 were female. The mean age was 48.6±10.2 years (range: 45-62 years); The mean interval from injury to operation was 7.2±1.4 days (range: 5-19 days); The mean operative time was 2.1±0.3 h (range: 1.0-3.2 hours); The mean intraoperative blood loss was 300±58.4 mL (range: 200-500 mL). Postoperative reduction (Matta's criteria) was deemed as excellent (n = 9), good (n = 4), and fair (n = 5). At the final follow-up, the hip function (modified Merle d'Aubigne-Postel scale) was deemed as excellent (n = 11), good (n = 3), and fair (n = 4). The mean union time was 4.5±1.8 months (range: 3-6 months). No implant failure, infection, heterotopic ossification, or neurovascular injury were reported.

conclusionThe oblique-ilioischial plate technique via anterior approach for acetabular fractures involving low posterior column offers reliable fixation, limited invasion, little intraoperative bleeding, and fewer complications. However, larger multicenter control studies are warranted.

Indexed as

Fractures, BoneHip FracturesNeck InjuriesSpinal FracturesAcetabulumAdultBlood Loss, SurgicalBone PlatesFemaleFracture Fixation, InternalHumansMaleMiddle AgedRetrospective StudiesTreatment OutcomeAcetabular fractureAnterior fixationmodified Stoppa approachOblique-ilioischial plate

Identifiers

PMID35668428
PMCPMC9169395
OpenAlexW4281638837

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.