Evidence map›Paper›PMID 35666028›Full record

ArticleAnimal models and experimental medicine2022

Continuous cardiac output measured with a Swan-Ganz catheter reacts too slowly in animal experiments with sudden circulatory failure.

Sigríður Olga Magnúsdóttir, Carsten Simonsen, Bodil Steen Rasmussen, Peter Enemark Lund, Benedict Kjaergaard

Open access · diamondAbstract read
In one paragraph

Article in Animal models and experimental medicine, 2022. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 5 papers.

0numbers the graph read from it
0cells of the map it votes in
5citing papers in PubMed
1.1field-weighted citation impact, top 24% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

5 citing papers in PubMed, 5 citations in OpenAlex.

  1. Article
  2. Article
  3. Article
  4. Review
  5. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

5 authors at 1 institution in 1 country.

Sigríður Olga MagnúsdóttirBiomedical Research Laboratory, Aalborg University Hospital, Aalborg, Denmark.
Carsten SimonsenDepartment of Cardiothoracic Surgery, Aalborg University Hospital, Aalborg, Denmark.
Bodil Steen RasmussenDepartment of Clinical Medicine, Aalborg University, Aalborg, Denmark.
Peter Enemark LundUnit of Clinical Biostatistics, Aalborg University Hospital, Aalborg, Denmark.
Benedict KjaergaardBiomedical Research Laboratory, Aalborg University Hospital, Aalborg, Denmark.ORCID 0000-0001-5797-7638
Aalborg University Hospital · DK

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

backgroundIn many animal experiments, it is vital to detect sudden changes in cardiac output (CO). This porcine study compared CO that was measured with a Swan-Ganz pulmonary catheter with the gold standard (which was a transit-time flow probe around the pulmonary artery) during interventions that caused hemodynamic instability.

methodsIn one series, 7 pigs were exposed to sudden changes in CO. In another series, 9 pigs experienced more prolonged changes in CO. All the pigs had a Swan-Ganz catheter placed into the pulmonary artery and a flow probe around the pulmonary artery. Adrenaline infusion and controlled hemorrhage were used to increase and decrease CO, respectively. The measurements of CO before and after each intervention were compared for correlation, agreement, and the time delay that it took each method to detect at least a 30% change in CO. A Bland-Altman test was used to identify correlations and agreements between the methods.

resultsIn the first series, there was a delay of 5-7 min for the Swan Ganz catheter to register a 30% change in cardiac output, compared with the flow probe. However, during prolonged changes in CO in the second series, there was a good correlation between the 2 methods. Mixed venous oxygen saturation reacted faster to changes than did CO; both were measured via the Swan-Ganz catheter.

conclusionsIn many animal studies, the use of Swan-Ganz catheters is suitable; however, in experiments with sudden hemodynamic instability, the flow probe is the most advantageous method for measuring CO.

Indexed as

Animal ExperimentationShockAnimalsCardiac OutputCatheterization, Swan-GanzCathetersSwinecardiac outputflow probehemodynamicspigsSwan-Ganz catheter

Identifiers

PMID35666028
PMCPMC9240745
OpenAlexW4281685114

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.