ReviewACS omega2022
Portable Devices for Measurement of Vitamin A Concentrations in Edible Oil: Field Readiness of Available Options.
Review in ACS omega, 2022. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 2 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
2 citing papers in PubMed, 6 citations in OpenAlex.
- Proposed RP-HPTLC-FLD kit for analysis of vitamin A palmitate in edible oils.Analytical and bioanalytical chemistry · 2025Article
- Digital tools and technologies used in food fortification: A scoping review.Annals of the New York Academy of Sciences · 2025Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
8 authors at 3 institutions in 2 countries.
Funding
Abstract
Vitamin A (VA) deficiency continues to be a major global health issue, despite measures to increase VA intake via consumption of staple foods such as edible oil. Portable quantitative and semiquantitative devices or test kits for internal quality control have the potential to overcome some of the limitations of traditional methods of testing, such as centralized laboratory, expensive equipment, and specially trained staff. This landscape analysis and comprehensive systematic mini-review catalogs and summarizes evidence on the analytical performance of portable quantitative and semiquantitative devices and test kits for the analysis of VA in edible oil. Studies or reports detailing the usability and validation of portable devices and/or test kits, as well as studies comparing device/test kit performance to a reference standard such as high-performance liquid chromatography (HPLC), were included. Identified devices and test kits were compared for performance versus the reference standard, usability, availability, and other characteristics. We identified four portable methods: two devices, the iCheck CHROMA and iCheck Chroma 3 from BioAnalyt; and two test kits, the QuickView from Bagco Enterprises and the Strategic Alliance for the Fortification of Vegetable Oils (SAFO) Test Kit by Badische Anilin and Soda Fabrik (BASF). Included studies reported the following: an internal validation of the portable method, a comparison of the portable method against a reference standard, a comparison of the portable method against another portable method, and several videos and company websites, which detailed device characteristics. iCheck CHROMA and QuickView quantified VA concentrations with high accuracy and precision compared to the reference standard for field-based quantification, were user-friendly, and provided results within 5 min. iCheck Chroma 3 requires more robust validation against a reference standard. We did not find data on internal validation or comparison against a reference standard for the current version of the SAFO test. Compared to QuickView and SAFO, the iCheck devices can transfer results to a hard drive or the Web, have an online order form for purchase, and meet a minimal set of criteria for point-of-need devices. iCheck, QuickView, and SAFO can quantify VA concentrations in the edible oils tested and determine whether a fortified oil meets country standards. Additional research is needed to validate these devices and test kits across additional oil types and document the ability to meet the minimal criteria for point-of-need devices suggested in this mini-review. Validation against a reference standard is required for SAFO. The limited number of portable methods available may be due to market saturation. Future market and use case analyses to inform the market size and utility of the different tests with publicly available data will allow new manufacturers, particularly those in lower-to-middle-income countries, to enter the market.
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.