Microgaskets for High-Channel-Density Reconnectable Implantable Packaging.

Paritosh Rustogi, Jack W Judy

Abstract read
In one paragraph

Article in Journal of microelectromechanical systems : a joint IEEE and ASME publication on microstructures, microactuators, microsensors, and microsystems, 2022. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.

0numbers the graph read from it
0cells of the map it votes in
1citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

1 citing paper in PubMed.

  1. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

2 authors.

Paritosh RustogiElectrical and Computer Engineering Department and the Nanoscience Institute for Medical and Engineering Technology, University of Florida, Gainesville, FL 32611 USA.
Jack W JudyElectrical and Computer Engineering Department, Biomedical Engineering Department, Department of Neurology, and the Nanoscience Institute for Medical and Engineering Technology, University of Florida, Gainesville, FL 32611 USA.

Funding

Reliable Miniature Implantable Connectors with High Channel Density for Advanced Neural-Interface ApplicationsR21EB028079 · NIBIB · UNIVERSITY OF FLORIDA · PI JUDY, JACK W · 2019 to 2020
$407k
NIBIB NIH HHS R21 EB028079
6 · The paper itself

Abstract

Demands for implantable bioelectronic devices to increase the number of channels for greater functional capacity and resolution, shrink implant size to minimize tissue response and patient burden, and support battery changes and electronics upgrades for long-term operational viability, cannot be met with existing implant-connector technology. In this paper we describe our novel approach to develop a rematable high-channel-density implant-connector technology, with a focus on the design, fabrication, and characterization of its microgasket. The microgaskets made of polydimethylsiloxane elastomer (PDMSe) have achieved much better electrical isolation for neural stimulation (~5 MΩ at 10 kHz) compared with conventional implant connectors (50 kΩ at 10 kHz), despite a 200-fold increase in channel density (conventional: ~0.0644 ch/mm

Indexed as

Channel IsolationImplantable ConnectorsMicrogasketsNeural interfaces