Evidence map›Paper›PMID 35662850›Full record

ArticleFrontiers in bioengineering and biotechnology2022

Performance Evaluation of a Novel Ultrafast Molecular Diagnostic Device Integrated With Microfluidic Chips and Dual Temperature Modules.

Shan Lin, Xiaojun Song, Kun Zhu, Quanyu Shao, Yinhang Chen, Wei Cheng, Zhijing Lei, Yu Chen, Yun Luo, Dazhi Jin

Abstract read
In one paragraph

Article in Frontiers in bioengineering and biotechnology, 2022. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 3 papers.

0numbers the graph read from it
0cells of the map it votes in
3citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

3 citing papers in PubMed.

  1. Article
  2. Article
  3. Rapid discrimination between clinicalFrontiers in microbiology · 2024
    Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

10 authors.

Shan LinSchool of Laboratory Medicine, Hangzhou Medical College, Hangzhou, China.
Xiaojun SongDepartment of Clinical Laboratory, Laboratory Medicine Center, Zhejiang Provincial People's Hospital, Hangzhou Medical College, Hangzhou, China.
Kun ZhuHangzhou Biochip for Diagnosis Technology Co., Ltd., Hangzhou, China.
Quanyu ShaoHangzhou Biochip for Diagnosis Technology Co., Ltd., Hangzhou, China.
Yinhang ChenHangzhou Biochip for Diagnosis Technology Co., Ltd., Hangzhou, China.
Wei ChengHangzhou Biochip for Diagnosis Technology Co., Ltd., Hangzhou, China.
Zhijing LeiHangzhou Biochip for Diagnosis Technology Co., Ltd., Hangzhou, China.
Yu ChenSchool of Laboratory Medicine, Hangzhou Medical College, Hangzhou, China.
Yun LuoSchool of Biotechnology and Biomolecular Sciences, University of New South Wales, Sydney, NSW, Australia.
Dazhi JinSchool of Laboratory Medicine, Hangzhou Medical College, Hangzhou, China.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Ultrafast, portable, and inexpensive molecular diagnostic platforms are critical for clinical diagnosis and on-site detection. There are currently no available real-time polymerase chain reaction (PCR) devices able to meet the demands of point-of-care testing, as the heating and cooling processes cannot be avoided. In this study, the dual temperature modules were first designed to process microfluidic chips automatically circulating between them. Thus, a novel ultrafast molecular diagnostic real-time PCR device (approximately 18 and 23 min for DNA and RNA detection, respectively) with two channels (FAM and Cy5) for the detection of 12 targets was developed. The device contained three core functional components, including temperature control, optics, and motion, which were integrated into a portable compact box. The temperature modules accurately control temperature in rapid thermal cycles with less than ±0.1 °C, ±1 °C and ±0.5 °C for the temperature fluctuation, uniformity, and error of indication, respectively. The average coefficient of variation (CV) of the fluorescence intensity (FI) for all 12 wells was 2.3% for FAM and 2.7% for Cy5. There was a good linear relationship between the concentrations of fluorescent dye and the FIs of FAM and Cy5(

Indexed as

dual temperature modulesmicrofluidic chipmolecular diagnosticperformance evaluationultrafast

Identifiers

PMID35662850
PMCPMC9162139

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked