ArticleComputer methods and programs in biomedicine2022
Modeling the biomechanics of the conventional aqueous outflow pathway microstructure in the human eye.
Article in Computer methods and programs in biomedicine, 2022. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 21 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
21 citing papers in PubMed.
- Article
- Scientific Concerns About Recent Fluid-Structure Interaction Models of the Aqueous Humor Outflow Pathway.Investigative ophthalmology & visual science · 2025Article
- Author Response: Scientific Concerns About Recent Fluid-Structure Interaction Models of the Aqueous Humor Outflow Pathway.Investigative ophthalmology & visual science · 2025Article
- 3D traction force microscopy in human trabecular meshwork tissues: Effects of ROCK and YAP/TAZ inhibition in normal and glaucomatous tissues.Tissue & cell · 2025Article
- Actin-microtubule synergy dominates force transmission and collagen strain in human trabecular meshwork.Acta biomaterialia · 2025Article
- Minimally Invasive Glaucoma Surgery Procedure in the Human Eye. A Fluid Structure Interaction Study.International journal for numerical methods in biomedical engineering · 2025Article
- Article
- Biomechanical properties of the trabecular meshwork in intraocular pressure regulation: a review.International ophthalmology · 2025Review
- High-resolution modeling of aqueous humor dynamics in the conventional outflow pathway of a normal human donor eye.Computer methods and programs in biomedicine · 2025Article
- The aqueous humour dynamics in primary angle closure disease: a computational study.The British journal of ophthalmology · 2025Article
- From tumor microenvironment to ocular hypertension: unraveling the pathogenesis and therapeutic strategies of cancer-related glaucoma.Frontiers in medicine · 2025Review
- Consensus Recommendations for Studies of Outflow Facility and Intraocular Pressure Regulation Using Ex Vivo Perfusion Approaches.Investigative ophthalmology & visual science · 2024Article
- Comparative analysis of traction forces in normal and glaucomatous trabecular meshwork cells within a 3D, active fluid-structure interaction culture environment.Acta biomaterialia · 2024Article
- Segmental biomechanics of the normal and glaucomatous human aqueous outflow pathway.Acta biomaterialia · 2024Article
- Implementing new computational methods for the study of JCT and SC inner wall basement membrane biomechanics and hydrodynamics.Computer methods and programs in biomedicine · 2024Article
- Biomechanics of the JCT and SC Inner Wall Endothelial Cells with Their Basement Membrane Using 3D Serial Block-Face Scanning Electron Microscopy.Bioengineering (Basel, Switzerland) · 2023Article
- Developing an experimental-computational workflow to study the biomechanics of the human conventional aqueous outflow pathway.Acta biomaterialia · 2023Article
- Morphological and biomechanical analyses of the human healthy and glaucomatous aqueous outflow pathway: Imaging-to-modeling.Computer methods and programs in biomedicine · 2023Article
- Modeling the Endothelial Glycocalyx Layer in the Human Conventional Aqueous Outflow Pathway.Cells · 2022Article
- The Effect of Intraocular Pressure Load Boundary on the Biomechanics of the Human Conventional Aqueous Outflow Pathway.Bioengineering (Basel, Switzerland) · 2022Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
7 authors.
Funding
Abstract
BACKGROUND AND
objectiveIntraocular pressure (IOP) is determined by aqueous humor outflow resistance, which is a function of the combined resistance of Schlemm's canal (SC) endothelium and the trabecular meshwork (TM) and their interactions in the juxtacanalicular connective tissue (JCT) region. Aqueous outflow in the conventional outflow pathway results in pressure gradient across the TM, JCT, and SC inner wall, and induces mechanical stresses and strains that influence the geometry and homeostasis of the outflow system. The outflow resistance is affected by alteration in tissues' geometry, so there is potential for active, two-way, fluid-structure interaction (FSI) coupling between the aqueous humor (fluid) and the TM, JCT, and SC inner wall (structure). However, our understanding of the biomechanical interactions of the aqueous humor with the outflow connective tissues and its contribution to the outflow resistance regulation is incomplete.
methodsIn this study, a microstructural finite element (FE) model of a human eye TM, JCT, and SC inner wall was constructed from a segmented, high-resolution histologic 3D reconstruction of the human outflow system. Three different elastic moduli (0.004, 0.128, and 51.5 MPa based on prior reports) were assigned to the TM/JCT complex while the elastic modulus of the SC inner wall was kept constant at 0.00748 MPa. The hydraulic conductivity was programmed separately for the TM, JCT, and SC inner wall using a custom subroutine. Cable elements were embedded into the TM and JCT extracellular matrix to represent the directional stiffness imparted by anisotropic collagen fibril orientation. The resultant stresses and strains in the outflow system were calculated using fluid-structure interaction method.
resultsThe higher TM/JCT stiffness resulted in larger stresses, but smaller strains in the outflow connective tissues, and resulted in a 4- and 5-fold larger pressure drop across the SC inner wall, respectively, compared to the most compliant model. Funneling through µm-sized SC endothelial pores was evident in the models at lower tissue stiffness, but aqueous flow was more turbulent in models with higher TM/JCT stiffness.
conclusionsThe mechanical properties of the outflow tissues play a crucial role in the hydrodynamics of the aqueous humor in the conventional outflow system.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.