ArticleJournal of orthopaedic surgery and research2022

Influence of fixed titanium plate position on the effectiveness of open-door laminoplasty for cervical spondylotic myelopathy.

Fa-Jing Liu, Xiao-Kun Ding, Yi Chai, Su-Hong Qi, Peng-Fei Li

Abstract read
In one paragraph

Article in Journal of orthopaedic surgery and research, 2022. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 6 papers.

0numbers the graph read from it
0cells of the map it votes in
6citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

6 citing papers in PubMed.

  1. Clinical efficacy and safety analysis of the "Pre-set screw path technique" in cervical posterior single door laminoplasty with supportive titanium plate fixation: a prospective randomized controlled study.European spine journal : official publication of the European Spine Society, the European Spinal Deformity Society, and the European Section of the Cervical Spine Research Society · 2026
    Trial
  2. Article
  3. Article
  4. Article
  5. Article
  6. Lamina Abrasion Caused by High-Speed Drill in Unilateral Door Cervical Laminoplasty: A Clinical Investigation.Medical science monitor : international medical journal of experimental and clinical research · 2023
    Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

5 authors.

Fa-Jing Liu *Department of Spine Surgery, Tianjin Hospital, No. 406, Jiefang Road, Hexi District, Tianjin, 300000, China. liufajing0707@163.com.
Xiao-Kun Ding *Department of Internal Medicine of Traditional Chinese Medicine, Tianjin Hospital, Tianjin, 300000, China.
Yi ChaiDepartment of Orthopedics, Hebei Provincial Hospital of Traditional Chinese Medicine, Shijiazhuang, 050013, China.
Su-Hong QiDepartment of Spine Surgery, Tianjin Hospital, No. 406, Jiefang Road, Hexi District, Tianjin, 300000, China.
Peng-Fei LiDepartment of Orthopedics, The People's Hospital of Hengshui City, Hengshui, 053000, China.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

backgroundDuring open-door laminoplasty, the position of the bone gutter is not fixed, and when the gutter migrates inward, the outer end of the titanium plate must be fixed on the lamina edge. It is unclear whether this will affect the clinical efficacy. This study aimed to observe the influence of the titanium plate fixation position on the effectiveness of open-door laminoplasty for cervical spondylotic myelopathy (CSM).

methodsA total of 98 patients with CSM who underwent open-door laminoplasty from August 2016 to October 2019 were included in this retrospective study. Fifty-five patients had the titanium plate fixed on the lateral mass (lateral mass group), and 43 patients had the titanium plate fixed on the lamina edge (lamina group). The opening angle, opening width, occurrence of hinge fracture, spinal cord drift distance, cervical curvature index (CCI), neurological function recovery (JOA score), neck function (NDI), C5 palsy and severity of axial symptoms were observed and compared between the two groups.

resultsThe opening angle in the lamina group was significantly larger than that in the lateral mass group, while the opening width and the spinal cord drift distance were significantly smaller than those in the lateral mass group (P < 0.05). The occurrence of hinge fracture in the lamina group was significantly higher than that in the lateral group (25.6% and 9.1%, respectively) (P < 0.05). The CCI was maintained well in both groups (P > 0.05), and there was no significant difference between the groups (P > 0.05). After surgery, the JOA score significantly increased in both groups (P < 0.05), and the neurological recovery rates were similar between the two groups (62.6% vs. 64.5%). The NDI score significantly decreased in both groups (P < 0.05), but the lateral mass group recovered to a greater degree than the lamina group (P < 0.05). The occurrence of C5 palsy was 2.3% in the lamina group and 14.5% in the lateral mass group, and there was a significant difference between the groups (P < 0.05). Postoperative axial symptom severity was significantly worse in the lamina group than in the lateral mass group (P < 0.05).

conclusionsIn open-door laminoplasty, it is feasible to fix the titanium plate on the lateral mass or to the lamina due to the same neurological function recovery. However, fixing it to the lamina will increase the opening angle and decrease the opening width, making the hinge prone to fracture and increasing the severity of postoperative axial symptoms.

Indexed as

LaminoplastySpinal Cord DiseasesCervical VertebraeHumansLaminectomyParalysisRetrospective StudiesTitaniumTreatment OutcomeTitaniumAxial symptomsC5 palsyCervical spondylotic myelopathyOpen-door laminoplastyTitanium plate

Identifiers

PMID35659017
PMCPMC9166363

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.