Evidence map›Paper›PMID 35659004›Full record

ArticleJournal of orthopaedic surgery and research2022

Femoral periprosthetic fracture treatment using the Ortho-Bridge System: a biomechanical study.

Yuntao Long, Yubin Qi, Guilai Zuo, Qingjie Zhang, Zhenlin Liu, Wen Wang

Abstract read
In one paragraph

Article in Journal of orthopaedic surgery and research, 2022. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 3 papers.

0numbers the graph read from it
0cells of the map it votes in
3citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

3 citing papers in PubMed.

  1. Article
  2. Article
  3. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

6 authors.

Yuntao Long *Shandong First Medical University & Shandong Academy Medical Sciences, Jinan, 250117, Shandong, China.
Yubin Qi *Department of Orthopaedics, The First Affiliated Hospital of Shandong First Medical University & Shandong Provincial Qianfoshan Hospital, Jinan, 250014, Shandong, China.
Guilai ZuoDepartment of Orthopaedics, The First Affiliated Hospital of Shandong First Medical University & Shandong Provincial Qianfoshan Hospital, Jinan, 250014, Shandong, China.
Qingjie ZhangNewton Laboratories, Tianjin Weiman Biomaterials Co., Ltd, Tianjin, 301600, China.
Zhenlin LiuNewton Laboratories, Tianjin Weiman Biomaterials Co., Ltd, Tianjin, 301600, China.
Wen WangDepartment of Orthopaedics, The First Affiliated Hospital of Shandong First Medical University & Shandong Provincial Qianfoshan Hospital, Jinan, 250014, Shandong, China. wangwenqfs@sina.com.ORCID http://orcid.org/0000-0002-8986-0781

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

backgroundWe undertook a comparative biomechanical study of type B1 fractures around femoral prostheses following cemented hip arthroplasty using the Ortho-Bridge System (OBS) and a locking compression plate/locking attachment plate structure (LCP + LAP). We aimed to investigate the biomechanical characteristics and advantages of the OBS compared with LCP + LAP when treating this fracture type.

methodsAn OBS fixation model was designed based on OBS and LCP + LAP fixation characteristics. The LCP + LAP combination (Group A) and three different OBS combinations (Groups B, C, and D) were used to fix a B1 fracture model with a femoral periprosthetic fracture. Axial compression and torsion experiments were then performed using simple and comminuted fracture models. The axial compression failure experiment was carried out, and the model stiffness during axial compression, torsion angle in torsion test, and vertical load in the final failure test were collected.

resultsWhen simulating simple oblique fractures, no significant difference was found among the four groups in terms of stiffness in the axial compression experiment (P = 0.257). The torsion angle of the LCP + LAP system was significantly higher compared with the OBS system (P < 0.05). When simulating a comminuted fracture, the experimental data for axial compression showed that the rigidity measurements of the three combinations of the OBS system were higher compared with the LCP + LAP system (P = 0.000) and that the torsion angles of three combinations of the OBS system were smaller compared with the LCP + LAP system (P < 0.05). In the axial compression failure test, the fixed failure mode of the LCP + LAP system was the destruction of the contact cortex at the fracture site, whereas the failure modes in the three OBS combinations involved fracture around the screws above the osteotomy and destruction of the contact cortex at the fracture site.

conclusionsThe findings revealed that the OBS produced superior biomechanical outcomes compared with LCP + LAP, especially for the bridging two-rod dual cortex. According to the performance observed after model axial compression destruction, the OBS was fixed and provided greater stress dispersion, which might make it more suitable for facilitating early functional movement and avoiding the failure of internal fixation.

Indexed as

Femoral FracturesFractures, ComminutedPeriprosthetic FracturesBiomechanical PhenomenaBone PlatesFracture Fixation, InternalHumansBiomechanical studyLocking Attachment PlateLocking Compression PlateOrtho-Bridge SystemVancouver B1 periprosthetic fracture

Identifiers

PMID35659004
PMCPMC9166506

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.