Evidence map›Paper›PMID 35657535›Full record

ArticleMagma (New York, N.Y.)2022

Characterizing geometric distortions of 3D sequences in clinical head MRI.

Katri Nousiainen, Teemu Mäkelä, Juha I Peltonen

Abstract read
In one paragraph

Article in Magma (New York, N.Y.), 2022. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.

0numbers the graph read from it
0cells of the map it votes in
1citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

1 citing paper in PubMed.

  1. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

3 authors.

Katri NousiainenHUS Medical Imaging Center, Helsinki University Hospital and University of Helsinki, Helsinki, Finland. katri.nousiainen@hus.fi.ORCID http://orcid.org/0000-0002-1283-5596
Teemu MäkeläHUS Medical Imaging Center, Helsinki University Hospital and University of Helsinki, Helsinki, Finland.ORCID http://orcid.org/0000-0003-3777-5283
Juha I PeltonenHUS Medical Imaging Center, Helsinki University Hospital and University of Helsinki, Helsinki, Finland.ORCID http://orcid.org/0000-0003-3731-3265

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

objectivePhantoms are often used to estimate the geometric accuracy in magnetic resonance imaging (MRI). However, the distortions may differ between anatomical and phantom images. This study aimed to investigate the applicability of a phantom-based and a test-subject-based method in evaluating geometric distortion present in clinical head-imaging sequences. MATERIALS AND

methodsWe imaged a 3D-printed phantom and test subjects with two MRI scanners using two clinical head-imaging 3D sequences with varying patient-table positions and receiver bandwidths. The geometric distortions were evaluated through nonrigid registrations: the displaced acquisitions were compared against the ideal isocenter positioning, and the varied bandwidth volumes against the volume with the highest bandwidth. The phantom acquisitions were also registered to a computed tomography scan.

resultsGeometric distortion magnitudes increased with larger table displacements and were in good agreement between the phantom and test-subject acquisitions. The effect of increased distortions with decreasing receiver bandwidth was more prominent for test-subject acquisitions.

conclusionPresented results emphasize the sensitivity of the geometric accuracy to positioning and imaging parameters. Phantom limitations may become an issue with some sequence types, encouraging the use of anatomical images for evaluating the geometric accuracy.

Indexed as

Magnetic Resonance ImagingTomography, X-Ray ComputedHumansPhantoms, ImagingArtifactsHealthcare quality assuranceMagnetic resonance imagingQuality control

Identifiers

PMID35657535
PMCPMC9596562

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.