Evidence map›Paper›PMID 35656705›Full record

ArticleOrthopaedic surgery2022

A Novel Method for Preoperative Positioning of Total Ankle Replacement Using 3D Digital Model.

Shi-Xun Wu, Shi-Zhang Liu, Ming Ling, Yan-Hui Che, Xin Tian, Xiang-Long Duan, Zhi Yi

Abstract read
In one paragraph

Article in Orthopaedic surgery, 2022. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

7 authors.

Shi-Xun WuDepartment of Orthopedics Surgery, Shaanxi Provincial People's Hospital, Xi'an Jiaotong University, Xi'an, China.ORCID https://orcid.org/0000-0001-9567-7476
Shi-Zhang LiuDepartment of Orthopedics Surgery, Shaanxi Provincial People's Hospital, Xi'an Jiaotong University, Xi'an, China.
Ming LingDepartment of Orthopedics Surgery, Shaanxi Provincial People's Hospital, Xi'an Jiaotong University, Xi'an, China.
Yan-Hui CheFirst Middle School of Xi'an City, Xi'an, China.
Xin TianDepartment of Orthopedics Surgery, Shaanxi Provincial People's Hospital, Xi'an Jiaotong University, Xi'an, China.
Xiang-Long DuanThe College of Life Sciences and Medicine, Northwest University, xi'an, China.
Zhi YiDepartment of Orthopedics Surgery, Shaanxi Provincial People's Hospital, Xi'an Jiaotong University, Xi'an, China.

Funding

Innovation Capability Support Program of Shaanxi 2019GHJD-14Key Research and Development Program of Shaanxi 2019ZDLSF02-09-01Key Research and Development Program of Shaanxi 2020GXLH-Y-019Research and DevelopmentScientific Research Program Funded by Shaanxi Provincial Education Department 18JC027Shaanxi Provincial Education DepartmentSocial Development Science and Technology Project of Shaanxi Province 2018ZDXM-SF-054Social Development Science and Technology Project of Shaanxi Province 2018ZDXM-SF-057Social Development Science and Technology Project of Shaanxi Province 2021SF-186
6 · The paper itself

Abstract

objectiveTo establish a digital model of the ankle joint through 3D imaging technology and explore the preoperative placement of ankle replacement prostheses.

methodsComputed tomography images of intact ankle joints from 54 cases in the outpatient and inpatient departments of our hospital were collected; according to the INBONE® total ankle system surgery process, the surgery model and surgical osteotomy were finished using MIMICS based on computer simulation method. The shortest distance was measured between the center point and the anterior, posterior, medial, and lateral, respectively, to ensure the precise position of the ankle replacement prosthesis by digital simulation surgery. The relationship between the two variables was analyzed by bivariate correlation analysis.

resultsThe dataset of this study included 48 cases of the sub-data set (26 males and 22 females) and included 27 cases of left ankle and 21 cases of right ankle. The average medial malleolar angle was 18.67°± 2.87°, the average amount of bone resection was 12.13 ± 1.86 cm

conclusionThe projection point of the lower tibia centerline on the tibial horizontal osteotomy surface is located at a position slightly anterior to the midpoint of the transverse diameter after ankle arthroplasty. The rational positioning of the total ankle replacement is located at both a position slightly anterior to the midpoint of the transverse diameter and midpoint of the anteroposterior diameter, which can be used as a reference method before total ankle arthroplasty surgery.

Indexed as

Arthroplasty, Replacement, AnkleAnkle JointComputer SimulationFemaleHumansMaleOsteotomyTibiaanatomical parametersankle arthritisankle joint replacementosteotomypreoperative planning

Identifiers

PMID35656705
PMCPMC9251280

What OpenQuestion holds

Textmetadata
LicenceCC BY-NC-ND
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.