ArticleOrthopaedic surgery2022
Effect of the In Situ Screw Implantation Region and Angle on the Stability of Lateral Lumbar Interbody Fusion: A Finite Element Study.
Article in Orthopaedic surgery, 2022. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 2 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
2 citing papers in PubMed, 2 citations in OpenAlex.
- The Anterolateral Transpedicular Transverse Process Screw Technique: Surgical Techniques, Biomechanical study and Preliminary Outcomes.Orthopaedic surgery · 2026Article
- The Influence of Screw Positioning on Cage Subsidence in Patients with Oblique Lumbar Interbody Fusion Combined with Anterolateral Fixation.Orthopaedic surgery · 2023Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
12 authors at 1 institution in 1 country.
Funding
Abstract
objectiveTo investigate the effect of the in situ screw implantation region and angle on the stability of lateral lumbar interbody fusion (LLIF) from a biomechanical perspective.
methodsA validated L2-4 finite element (FE) model was modified for simulation. The L3-4 fused segment undergoing LLIF surgery was modeled. The area between the superior and inferior edges and the anterior and posterior edges of the vertebral body (VB) is divided into four zones by three parallel lines in coronal and horizontal planes. In situ screw implantation methods with different angles based on the three parallel lines in coronal plane were applied in Models A, B, and C (A: parallel to inferior line; B: from inferior line to midline; C: from inferior line to superior line). In addition, four implantation methods with different regions based on the three parallel lines in horizontal plane were simulated as types 1-2, 1-3, 2-2, and 2-3 (1-2: from anterior line to midline; 1-3: from anterior line to posterior line; 2-2: parallel to midline; 2-3: from midline to posterior line). L3-4 ROM, interbody cage stress, screw-bone interface stress, and L4 superior endplate stress were tracked and calculated for comparisons among these models.
resultsThe L3-4 ROM of Models A, B, and C decreased with the extent ranging from 47.9% (flexion-extension) to 62.4% (lateral bending) with no significant differences under any loading condition. Types 2-2 and 2-3 had 45% restriction, while types 1-2 and 1-3 had 51% restriction in ROM under flexion-extension conditions. Under lateral bending, types 2-2 and 2-3 had 70.6% restriction, while types 1-2 and 1-3 had 61.2% restriction in ROM. Under axial rotation, types 2-2 and 2-3 had 65.2% restriction, while types 1-2 and 1-3 had 59.3% restriction in ROM. The stress of the cage in types 2-2 and 2-3 was approximately 20% lower than that in types 1-2 and 1-3 under all loading conditions in all models. The peak stresses at the screw-bone interface in types 2-2 and 2-3 were much lower (approximately 35%) than those in types 1-2 and 1-3 under lateral bending, while no significant differences were observed under flexion-extension and axial rotation. The peak stress on the L4 superior endplate was approximately 30 MPa and was not significantly different in all models under any loading condition.
conclusionsDifferent regions of entry-exit screws induced multiple screw trajectories and influenced the stability and mechanical responses. However, different implantation angles did not. Considering the difficulty of implantation, the ipsilateral-contralateral trajectory in the lateral middle region of the VB can be optimal for in situ screw implantation in LLIF surgery.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.