Evidence map›Paper›PMID 35656700›Full record

ArticleOrthopaedic surgery2022

Effect of the In Situ Screw Implantation Region and Angle on the Stability of Lateral Lumbar Interbody Fusion: A Finite Element Study.

Guangye Zhu, Zhihua Wu, Zhichao Fang, Peng Zhang, Jiahui He, Xiang Yu, Zhilin Ge, Kai Tang, De Liang, Xiaobing Jiang and 2 more

Open access · goldAbstract read
In one paragraph

Article in Orthopaedic surgery, 2022. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 2 papers.

0numbers the graph read from it
0cells of the map it votes in
2citing papers in PubMed
0.3field-weighted citation impact, top 45% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

2 citing papers in PubMed, 2 citations in OpenAlex.

  1. Article
  2. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

12 authors at 1 institution in 1 country.

Guangye Zhu1st Clinical Medical College, Guangzhou University of Chinese Medicine, Guangzhou, China.
Zhihua Wu1st Clinical Medical College, Guangzhou University of Chinese Medicine, Guangzhou, China.
Zhichao Fang1st Clinical Medical College, Guangzhou University of Chinese Medicine, Guangzhou, China.
Peng Zhang1st Clinical Medical College, Guangzhou University of Chinese Medicine, Guangzhou, China.
Jiahui He1st Clinical Medical College, Guangzhou University of Chinese Medicine, Guangzhou, China.
Xiang YuDepartment of Spinal Surgery, 1st Affiliated Hospital of Guangzhou University of Chinese Medicine, Guangzhou, China.
Zhilin Ge1st Clinical Medical College, Guangzhou University of Chinese Medicine, Guangzhou, China.
Kai Tang1st Clinical Medical College, Guangzhou University of Chinese Medicine, Guangzhou, China.
De LiangDepartment of Spinal Surgery, 1st Affiliated Hospital of Guangzhou University of Chinese Medicine, Guangzhou, China.
Xiaobing JiangDepartment of Spinal Surgery, 1st Affiliated Hospital of Guangzhou University of Chinese Medicine, Guangzhou, China.ORCID https://orcid.org/0000-0002-8009-0282
Ziyang Liang1st Clinical Medical College, Guangzhou University of Chinese Medicine, Guangzhou, China.
Jianchao CuiDepartment of Spinal Surgery, 1st Affiliated Hospital of Guangzhou University of Chinese Medicine, Guangzhou, China.ORCID https://orcid.org/0000-0003-4485-0886
Guangzhou University of Chinese Medicine · CN

Funding

Excellent Young Scholars Project of the First Affiliated Hospital of Guangzhou University of Chinese Medicine 2019QN17Natural Science Foundation of Changsha City kq2202390Scientific Research Project of Traditional Chinese Medicine Bureau of Guangdong Province 20201097
6 · The paper itself

Abstract

objectiveTo investigate the effect of the in situ screw implantation region and angle on the stability of lateral lumbar interbody fusion (LLIF) from a biomechanical perspective.

methodsA validated L2-4 finite element (FE) model was modified for simulation. The L3-4 fused segment undergoing LLIF surgery was modeled. The area between the superior and inferior edges and the anterior and posterior edges of the vertebral body (VB) is divided into four zones by three parallel lines in coronal and horizontal planes. In situ screw implantation methods with different angles based on the three parallel lines in coronal plane were applied in Models A, B, and C (A: parallel to inferior line; B: from inferior line to midline; C: from inferior line to superior line). In addition, four implantation methods with different regions based on the three parallel lines in horizontal plane were simulated as types 1-2, 1-3, 2-2, and 2-3 (1-2: from anterior line to midline; 1-3: from anterior line to posterior line; 2-2: parallel to midline; 2-3: from midline to posterior line). L3-4 ROM, interbody cage stress, screw-bone interface stress, and L4 superior endplate stress were tracked and calculated for comparisons among these models.

resultsThe L3-4 ROM of Models A, B, and C decreased with the extent ranging from 47.9% (flexion-extension) to 62.4% (lateral bending) with no significant differences under any loading condition. Types 2-2 and 2-3 had 45% restriction, while types 1-2 and 1-3 had 51% restriction in ROM under flexion-extension conditions. Under lateral bending, types 2-2 and 2-3 had 70.6% restriction, while types 1-2 and 1-3 had 61.2% restriction in ROM. Under axial rotation, types 2-2 and 2-3 had 65.2% restriction, while types 1-2 and 1-3 had 59.3% restriction in ROM. The stress of the cage in types 2-2 and 2-3 was approximately 20% lower than that in types 1-2 and 1-3 under all loading conditions in all models. The peak stresses at the screw-bone interface in types 2-2 and 2-3 were much lower (approximately 35%) than those in types 1-2 and 1-3 under lateral bending, while no significant differences were observed under flexion-extension and axial rotation. The peak stress on the L4 superior endplate was approximately 30 MPa and was not significantly different in all models under any loading condition.

conclusionsDifferent regions of entry-exit screws induced multiple screw trajectories and influenced the stability and mechanical responses. However, different implantation angles did not. Considering the difficulty of implantation, the ipsilateral-contralateral trajectory in the lateral middle region of the VB can be optimal for in situ screw implantation in LLIF surgery.

Indexed as

Pedicle ScrewsSpinal FusionBiomechanical PhenomenaBone ScrewsFinite Element AnalysisHumansLumbar VertebraeRange of Motion, ArticularFinite element analysisIn situ screwLateral lumbar interbody fusionStabilitySurgical procedures

Identifiers

PMID35656700
PMCPMC9251290
OpenAlexW4281648426

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390