ArticleClinical ophthalmology (Auckland, N.Z.)2022
Comparison of Three Tonometers in Measuring Intraocular Pressure in Eyes That Underwent Myopic Laser in situ Keratomileusis and Photorefractive Keratectomy.
Article in Clinical ophthalmology (Auckland, N.Z.), 2022. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 5 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
5 citing papers in PubMed, 9 citations in OpenAlex.
- Underestimation of Intraocular Pressure (IOP) After LASIK and PRK: Systematic Review and Meta-Analysis.Journal of clinical medicine · 2026Review
- Comparison of intraocular pressure measurements obtained by Goldmann applanation tonometer, corvis ST and a conventional non-contact airpuff tonometer in eyes with previous myopic refractive surgery and correlation with corneal biomechanical parameters.International ophthalmology · 2025Observational
- Considerations for Glaucoma Evaluation and Management in Refractive Surgery Candidates.Clinical ophthalmology (Auckland, N.Z.) · 2025Review
- Refractive surgery in glaucoma and suspected glaucoma patients: Critical analysis of the literature and clinical recommendations.Arquivos brasileiros de oftalmologia · 2025Review
- Intraocular Pressure Measurements in Standing, Sitting, Prone, and Supine Positions.Journal of personalized medicine · 2024Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
5 authors at 1 institution in 1 country.
Funding
No grant is acknowledged in the PubMed record.
Abstract
Objective: To compare the intraocular pressure (IOP) obtained by Goldmann applanation tonometer (GAT), correcting applanation tonometer surface (CATS) and biomechanically corrected IOP (bIOP) of Corvis ST tonometer (CVS); and to determine the effects of manifest refraction spherical equivalent (MRSE), central corneal thickness (CCT) and mean corneal curvature (Km) on the IOP measurements of corneal refractive patients. Methods: This was a single-center, retrospective, cross-sectional study of 120 eyes of 64 patients from May 1, 2020 to June 1, 2021 who underwent laser in situ keratomileusis (LASIK) or photorefractive keratectomy (PRK). The level of agreement between the three tonometers was evaluated, and correlation between parameters was calculated using Pearson correlation. Results: Mean preoperative to postoperative IOP in LASIK and PRK was 15.1 ± 3 to 11.3 ± 2.1 and 14.4 ± 2.6 to 12.1 ± 3 using GAT, 16.4 ± 2.8 to 13.1 ± 2.3 and 15.9 ± 2.6 to 13.7 ± 3 using CATS and 14.8 ± 2.4 to 12.9 ± 1.5 and 14.2 ± 2.4 to 12.6 ± 1.9 using CVS-bIOP. Preoperative IOP correlation between each tonometer pair showed that the lowest mean difference was between GAT and CVS-bIOP (0.32 in LASIK, 0.15 in PRK). Preoperative to postoperative IOP correlation of each tonometer resulted in a difference of 3.77, 2.30 in GAT; 3.32, 2.28 in CATS and 1.88, 1.62 in CVS-bIOP in the LASIK and PRK groups, respectively. Percentage change in CCT and Km was not correlated while change in MRSE had a weak relationship with percentage change in CVS-bIOP. Conclusion: Preoperatively, GAT and CVS-bIOP had the best agreement in IOP measurements. CATS recorded the highest IOP preoperatively and postoperatively. IOP decreased in the three tonometers after LASIK and PRK with GAT having the largest decrease. CVS-bIOP had the lowest change between preoperative and postoperative IOP measurements. Only percentage change in MRSE was correlated with percentage change in CVS-bIOP in the LASIK group.
Indexed as
Identifiers
What OpenQuestion holds