Synthesis of magnetic resonance images from computed tomography data using convolutional neural network with contextual loss function.
Article in Quantitative imaging in medicine and surgery, 2022. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 6 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
6 citing papers in PubMed.
- Deep learning-based multi-modality image conversion for evaluating dose calculation and position correction accuracy in image-guided radiation therapy.Radiological physics and technology · 2026Article
- Letter to the Editor: "Feasibility study on the clinical application of CT-based synthetic brain T1-weighted MRI: comparison with conventional T1-weighted MRI".European radiology · 2025Article
- Reply to Letter to the Editor: "Feasibility study on the clinical application of CT-based synthetic brain T1-weighted MRI: comparison with conventional T1-weighted MRI".European radiology · 2025Article
- Feasibility study on the clinical application of CT-based synthetic brain T1-weighted MRI: comparison with conventional T1-weighted MRI.European radiology · 2024Article
- Neurosonographic Classification in Premature Infants Receiving Omega-3 Supplementation Using Convolutional Neural Networks.Diagnostics (Basel, Switzerland) · 2024Article
- The automatic evaluation of steno-occlusive changes in time-of-flight magnetic resonance angiography of moyamoya patients using a 3D coordinate attention residual network.Quantitative imaging in medicine and surgery · 2023Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
8 authors.
Funding
No grant is acknowledged in the PubMed record.
Abstract
Background: Magnetic resonance imaging (MRI) images synthesized from computed tomography (CT) data can provide more detailed information on pathological structures than that of CT data alone; thus, the synthesis of MRI has received increased attention especially in medical scenarios where only CT images are available. A novel convolutional neural network (CNN) combined with a contextual loss function was proposed for synthesis of T1- and T2-weighted images (T1WI and T2WI) from CT data. Methods: A total of 5,053 and 5,081 slices of T1WI and T2WI, respectively were selected for the dataset of CT and MRI image pairs. Affine registration, image denoising, and contrast enhancement were done on the aforementioned multi-modality medical image dataset comprising T1WI, T2WI, and CT images of the brain. A deep CNN was then proposed by modifying the ResNet structure to constitute the encoder and decoder of U-Net, called double ResNet-U-Net (DRUNet). Three different loss functions were utilized to optimize the parameters of the proposed models: mean squared error (MSE) loss, binary crossentropy (BCE) loss, and contextual loss. Statistical analysis of the independent-sample Results: DRUNet-101 with contextual loss yielded higher values of peak signal-to-noise ratio (PSNR), structural similarity index measure (SSIM), and Tenengrad function (i.e., 34.25±2.06, 0.97±0.03, and 17.03±2.75 for T1WI and 33.50±1.08, 0.98±0.05, and 19.76±3.54 for T2WI respectively). The results were statistically significant at P<0.001 with a narrow confidence interval of difference, indicating the superiority of DRUNet-101 with contextual loss. In addition, both image zooming and difference maps presented for the final synthetic MR images visually reflected the robustness of DRUNet-101 with contextual loss. The visualization of convolution filters and feature maps showed that the proposed model can generate synthetic MR images with high-frequency information. Conclusions: The results demonstrated that DRUNet-101 with contextual loss function provided better high-frequency information in synthetic MR images compared with the other two functions. The proposed DRUNet model has a distinct advantage over previous models in terms of PSNR, SSIM, and Tenengrad score. Overall, DRUNet-101 with contextual loss is recommended for synthesizing MR images from CT scans.