Evidence map›Paper›PMID 35650624›Full record

ArticleJournal of cardiovascular magnetic resonance : official journal of the Society for Cardiovascular Magnetic Resonance2022

Improved catheter tracking during cardiovascular magnetic resonance-guided cardiac catheterization using overlay visualization.

Joshua S Greer, Mohamed Abdelghafar Hussein, Ravi Vamsee, Yousef Arar, Sascha Krueger, Steffen Weiss, Jeanne Dillenbeck, Gerald Greil, Surendranath R Veeram Reddy, Tarique Hussain

Abstract read
In one paragraph

Article in Journal of cardiovascular magnetic resonance : official journal of the Society for Cardiovascular Magnetic Resonance, 2022. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 11 papers.

0numbers the graph read from it
0cells of the map it votes in
11citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

11 citing papers in PubMed.

  1. Article
  2. Article
  3. Review
  4. Article
  5. Article
  6. Article
  7. Article
  8. Article
  9. Interventional cardiovascular magnetic resonance: state-of-the-art.Journal of cardiovascular magnetic resonance : official journal of the Society for Cardiovascular Magnetic Resonance · 2023
    Review
  10. Article
  11. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

10 authors.

Joshua S GreerDepartment of Pediatrics, University of Texas Southwestern Medical Center, 5323 Harry Hines Blvd, Dallas, TX, 75390, USA. joshua.greer@utsouthwestern.edu.ORCID 0000-0002-1423-6781
Mohamed Abdelghafar HusseinDepartment of Pediatrics, University of Texas Southwestern Medical Center, 5323 Harry Hines Blvd, Dallas, TX, 75390, USA.
Ravi VamseeDepartment of Pediatrics, University of Texas Southwestern Medical Center, 5323 Harry Hines Blvd, Dallas, TX, 75390, USA.
Yousef ArarDepartment of Pediatrics, University of Texas Southwestern Medical Center, 5323 Harry Hines Blvd, Dallas, TX, 75390, USA.
Sascha KruegerPhilips Research Laboratories, Philips GmbH Innovative Technologies, Hamburg, Germany.
Steffen WeissPhilips Research Laboratories, Philips GmbH Innovative Technologies, Hamburg, Germany.
Jeanne DillenbeckDepartment of Pediatrics, University of Texas Southwestern Medical Center, 5323 Harry Hines Blvd, Dallas, TX, 75390, USA.
Gerald GreilDepartment of Pediatrics, University of Texas Southwestern Medical Center, 5323 Harry Hines Blvd, Dallas, TX, 75390, USA.
Surendranath R Veeram ReddyDepartment of Pediatrics, University of Texas Southwestern Medical Center, 5323 Harry Hines Blvd, Dallas, TX, 75390, USA.
Tarique HussainDepartment of Pediatrics, University of Texas Southwestern Medical Center, 5323 Harry Hines Blvd, Dallas, TX, 75390, USA.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

introductionCardiovascular magnetic resonance (CMR)-guided cardiac catheterization is becoming more widespread due to the ability to acquire both functional CMR measurements and diagnostic catheterization data without exposing patients to ionizing radiation. However, the real-time imaging sequences used for catheter guidance during these procedures are limited in resolution and the anatomical detail they can provide. In this study, we propose a passive catheter tracking approach which simultaneously improves catheter tracking and visualization of the anatomy.

methods60 patients with congenital heart disease underwent CMR-guided cardiac catheterization on a 1.5T CMR scanner (Ingenia, Philips Healthcare, Best the Netherlands) using the Philips iSuite system. The proposed T1-overlay technique uses a commercially available heavily T1-weighted sequence to image the catheter, and overlays it on a high-resolution 3D dataset within iSuite in real-time. Suppressed tissue in the real-time images enables the use of a thick imaging slab to assist in tracking of the catheter. Improvement in catheter visualization time was compared between T1-overlay and the conventional invasive CMR (iCMR) balanced steady state free precession (bSSFP) sequence. This technique also enabled selective angiography visualization for real-time evaluation of blood flow dynamics (such as pulmonary transit time), similar to direct contrast injection under standard fluoroscopy. Estimates of pulmonary transit time using iCMR were validated using x-ray fluoroscopy in 16 patients.

resultsThe T1-overlay approach significantly increased the time that the catheter tip was kept in view by the technologist compared to the bSSFP sequence conventionally used for iCMR. The resulting images received higher ratings for blood/balloon contrast, anatomy visualization, and overall suitability for iCMR guidance by three cardiologists. iCMR selective angiography using T1-overlay also provided accurate estimates of pulmonary transit time that agreed well with x-ray fluoroscopy.

conclusionWe demonstrate a new passive catheter tracking technique using the iSuite platform that improves visualization of the catheter and cardiac anatomy. These improvements significantly increase the time that the catheter tip is seen throughout the procedure. We also demonstrate the feasibility of iCMR selective angiography for the measurement of pulmonary transit time.

Indexed as

Magnetic Resonance Imaging, InterventionalCardiac CatheterizationCathetersHumansMagnetic Resonance SpectroscopyPredictive Value of TestsCardiac catheterizationCongenital heart diseaseInvasive CMRPediatrics

Identifiers

PMID35650624
PMCPMC9161533

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.