Evidence map›Paper›PMID 35647013›Full record

ArticleFrontiers in surgery2022

An Efficient Needleless Grasping Suture Technique for Graft Preparation in Anterior Cruciate Ligament Reconstruction.

Chaohua Fang, Rongshan Cheng, Jian Jiang, Dimitris Dimitriou, Huizhi Wang, Ziang Jiang, Tsung-Yuan Tsai, Cheng-Kung Cheng

Open access · goldAbstract read
In one paragraph

Article in Frontiers in surgery, 2022. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 2 papers, 1 of them a synthesis that pooled it.

0numbers the graph read from it
0cells of the map it votes in
2citing papers in PubMed, 1 pooled it
0.7field-weighted citation impact, top 32% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

2 citing papers in PubMed, 1 synthesis or guideline pooled it, 3 citations in OpenAlex.

  1. Pooled it
  2. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

8 authors at 5 institutions in 2 countries.

Chaohua FangDepartment of Sports Medicine, Ningbo No. 6 Hospital, Zhejiang, China.
Rongshan ChengSchool of Biomedical Engineering and Med-X Research Institute, Shanghai Jiao Tong University, Shanghai, China.
Jian JiangDepartment of Operating Room, Ningbo No. 6 Hospital, Zhejiang, China.
Dimitris DimitriouDepartment of Orthopedics, Balgrist University Hospital, Zürich, Switzerland.
Huizhi WangSchool of Biomedical Engineering and Med-X Research Institute, Shanghai Jiao Tong University, Shanghai, China.
Ziang JiangSchool of Biomedical Engineering and Med-X Research Institute, Shanghai Jiao Tong University, Shanghai, China.
Tsung-Yuan TsaiSchool of Biomedical Engineering and Med-X Research Institute, Shanghai Jiao Tong University, Shanghai, China.
Cheng-Kung ChengSchool of Biomedical Engineering and Med-X Research Institute, Shanghai Jiao Tong University, Shanghai, China.
Shanghai Jiao Tong University · CNMinistry of Education of the People's Republic of China · CNNingbo No.6 Hospital · CNShanghai Ninth People's Hospital · CNUniversitätsklinik Balgrist · CH

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Objective: Several needleless techniques have been developed to outcome the inherent disadvantages of the traditional needle stitching technique for graft preparation, such as tendon damage through the needle, time consumption, and the potential risk of needlestick injury. The purpose of the present study is to compare the graft preparation time and the biomechanical performance between an efficient needleless technique and the traditional needle stitching technique for graft preparation in anterior cruciate ligament reconstruction (ACLR). Methods: The time required to perform a complete suture on 20 hamstring tendons during ACLRs was measured. The grafts from one side were prepared using the needle stitching technique. The grafts from the other side used the needleless grasping suture technique. For the second part of the study, 12 fresh-frozen porcine flexor tendons were divided into two groups using two techniques and were mounted in an electric tensile test system. Each group was pretensioned to 100 N to simulate the maximum initial graft tension. The suturing state of sutures and graft (intact and damaged) and the load-elongation curve were recorded for each group. A Student's Results: In operation, the needleless grasping suture technique group (19.8 ± 4.8, range: 13.5-32.9 s) was significantly faster ( Conclusion: The needleless grasping suture technique was a convenient and efficient method for graft preparation in ACLR.

Indexed as

anterior cruciate ligament reconstructionbiomechanical performancegraft preparation timeneedleless grasping suture techniqueneedle stitching technique

Identifiers

PMID35647013
PMCPMC9133538
OpenAlexW4280638493

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.