Evidence map›Paper›PMID 35645618›Full record

ArticleProceedings of the ... IEEE International Conference on Acoustics, Speech, and Signal Processing. ICASSP (Conference)2022

MRI RECOVERY WITH A SELF-CALIBRATED DENOISER.

Sizhuo Liu, Philip Schniter, Rizwan Ahmad

Abstract read
In one paragraph

Article in Proceedings of the ... IEEE International Conference on Acoustics, Speech, and Signal Processing. ICASSP (Conference), 2022. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 2 papers.

0numbers the graph read from it
0cells of the map it votes in
2citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

2 citing papers in PubMed.

  1. Article
  2. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

3 authors.

Sizhuo LiuDepartment of Biomedical Engineering, Ohio State University, Columbus OH, 43210, USA.
Philip SchniterDepartment of Electrical and Computer Engineering, Ohio State University, Columbus OH, 43210, USA.
Rizwan AhmadDepartment of Biomedical Engineering, Ohio State University, Columbus OH, 43210, USA.

Funding

A New Paradigm for Rapid, Accurate Cardiac Magnetic Resonance ImagingR01HL135489 · NHLBI · OHIO STATE UNIVERSITY · PI AHMAD, RIZWAN · 2017 to 2021
$3.0M
A comprehensive deep learning framework for MRI reconstructionR01EB029957 · NIBIB · OHIO STATE UNIVERSITY · PI AHMAD, RIZWAN, SCHNITER, PHILIP · 2021 to 2024
$2.3M
NHLBI NIH HHS R01 HL135489NIBIB NIH HHS R01 EB029957
6 · The paper itself

Abstract

Plug-and-play (PnP) methods that employ application-specific denoisers have been proposed to solve inverse problems, including MRI reconstruction. However, training application-specific denoisers is not feasible for many applications due to the lack of training data. In this work, we propose a PnP-inspired recovery method that does not require data beyond the single, incomplete set of measurements. The proposed self-supervised method, called recovery with a self-calibrated denoiser (ReSiDe), trains the denoiser from the patches of the image being recovered. The denoiser training and a call to the denoising subroutine are performed in each iteration of a PnP algorithm, leading to a progressive refinement of the reconstructed image. For validation, we compare ReSiDe with a compressed sensing-based method and a PnP method with BM3D denoising using single-coil MRI brain data.

Indexed as

denoisingMRI reconstructionplug-and-playself-supervised learningunsupervised learning

Identifiers

PMID35645618
PMCPMC9134859

What OpenQuestion holds

Textmetadata
LicenceTDM
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.