Evidence map›Paper›PMID 35643823›Full record

ArticleJournal of biomedical optics2022

Label-free multimodal nonlinear optical imaging of needle biopsy cores for intraoperative cancer diagnosis.

Lingxiao Yang, Jaena Park, Eric J Chaney, Janet E Sorrells, Marina Marjanovic, Heidi Phillips, Darold R Spillman, Stephen A Boppart

Open access · goldAbstract read
In one paragraph

Article in Journal of biomedical optics, 2022. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 6 papers.

0numbers the graph read from it
0cells of the map it votes in
6citing papers in PubMed
0.9field-weighted citation impact, top 31% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

6 citing papers in PubMed, 12 citations in OpenAlex.

  1. Integrating nonlinear optical and Raman spectral imaging for label-free pathological examinations.Photochemical & photobiological sciences : Official journal of the European Photochemistry Association and the European Society for Photobiology · 2025
    Article
  2. Article
  3. Article
  4. Article
  5. Article
  6. Nonlinear Imaging Histopathology: A Pipeline to Correlate Gold-Standard Hematoxylin and Eosin Staining With Modern Nonlinear Microscopy.IEEE journal of selected topics in quantum electronics : a publication of the IEEE Lasers and Electro-optics Society
    Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

8 authors at 2 institutions in 1 country.

Lingxiao YangUniversity of Illinois at Urbana-Champaign, Department of Electrical and Computer Engineering, Urban, United States.
Jaena ParkUniversity of Illinois at Urbana-Champaign, Beckman Institute for Advanced Science and Technology, U, United States.
Eric J ChaneyUniversity of Illinois at Urbana-Champaign, Beckman Institute for Advanced Science and Technology, U, United States.
Janet E SorrellsUniversity of Illinois at Urbana-Champaign, Beckman Institute for Advanced Science and Technology, U, United States.
Marina MarjanovicUniversity of Illinois at Urbana-Champaign, Beckman Institute for Advanced Science and Technology, U, United States.
Heidi PhillipsUniversity of Illinois at Urbana-Champaign, College of Veterinary Medicine, Urbana, Illinois, United States.
Darold R SpillmanUniversity of Illinois at Urbana-Champaign, Beckman Institute for Advanced Science and Technology, U, United States.
Stephen A BoppartUniversity of Illinois at Urbana-Champaign, Department of Electrical and Computer Engineering, Urban, United States.
University of Illinois Urbana-Champaign · USUniversity of Illinois System · US

Funding

Intraoperative Polarization-Sensitive OCT for Assessing Breast Tumor MarginsR01CA213149 · NCI · UNIVERSITY OF ILLINOIS AT URBANA-CHAMPAIGN · PI BOPPART, STEPHEN A · 2017 to 2021
$2.4M
Optical Amplification Microscopy of Weak Back-Scattered LightR01EB023232 · NIBIB · UNIVERSITY OF ILLINOIS AT URBANA-CHAMPAIGN · PI BOPPART, STEPHEN A · 2016 to 2019
$1.8M
Imaging tumor microenvironment by Optical Fiber-Tethered Simultaneous Lifetime-resolved Autofluorescence-Multiharmonic (OFT-SLAM) microscopyR01CA241618 · NCI · UNIVERSITY OF ILLINOIS AT URBANA-CHAMPAIGN · PI BOPPART, STEPHEN A, TU, HAOHUA · 2019 to 2022
$1.6M
NCI NIH HHS R01 CA213149NCI NIH HHS R01 CA241618NIBIB NIH HHS R01 EB023232
6 · The paper itself

Abstract

significanceNeedle biopsy (NB) procedures are important for the initial diagnosis of many types of cancer. However, the possibility of NB specimens being unable to provide diagnostic information, (i.e., non-diagnostic sampling) and the time-consuming histological evaluation process can cause delays in diagnoses that affect patient care.

aimWe aim to demonstrate the advantages of this label-free multimodal nonlinear optical imaging (NLOI) technique as a non-destructive point-of-procedure evaluation method for NB tissue cores, for the visualization and characterization of the tissue microenvironment. APPROACH: A portable, label-free, multimodal NLOI system combined second-harmonic generation (SHG) and third-harmonic generation and two- and three-photon autofluorescence (2PF, 3PF) microscopy. It was used for intraoperative imaging of fresh NB tissue cores acquired during canine cancer surgeries, which involved liver, lung, and mammary tumors as well as soft-tissue sarcoma; in total, eight canine patients were recruited. An added tissue culture chamber enabled the use of this NLOI system for longitudinal imaging of fresh NB tissue cores taken from an induced rat mammary tumor and healthy mouse livers.

resultsThe intraoperative NLOI system was used to assess fresh canine NB specimens during veterinary cancer surgeries. Histology-like morphological features were visualized by the combination of four NLOI modalities at the point-of-procedure. The NLOI results provided quantitative information on the tissue microenvironment such as the collagen fiber orientation using Fourier-domain SHG analysis and metabolic profiling by optical redox ratio (ORR) defined by 2PF/(2PF + 3PF). The analyses showed that the canine mammary tumor had more randomly oriented collagen fibers compared to the tumor margin, and hepatocarcinoma had a wider distribution of ORR with a lower mean value compared to the liver fibrosis and the normal-appearing liver. Moreover, the loss of metabolic information during tissue degradation of fresh murine NB specimens was shown by overall intensity decreases in all channels and an increase of mean ORR from 0.94 (standard deviation 0.099) to 0.97 (standard deviation 0.077) during 1-h longitudinal imaging of a rat mammary tumor NB specimen. The tissue response to staurosporine (STS), an apoptotic inducer, from fresh murine liver NB specimens was also observed. The mean ORR decreased from 0.86 to 0.74 in the first 40 min and then increased to 0.8 during the rest of the hour of imaging, compared to the imaging results without the addition of STS, which showed a continuous increase of ORR from 0.72 to 0.75.

conclusionsA label-free, multimodal NLOI platform reveals microstructural and metabolic information of the fresh NB cores during intraoperative cancer imaging. This system has been demonstrated on animal models to show its potential to provide a more comprehensive histological assessment and a better understanding of the unperturbed tumor microenvironment. Considering tissue degradation, or loss of viability upon fixation, this intraoperative NLOI system has the advantage of immediate assessment of freshly excised tissue specimens at the point of procedure.

Indexed as

Breast NeoplasmsMultimodal ImagingAnimalsBiopsy, NeedleCollagenDogsFemaleHumansMiceOptical ImagingRatsTumor MicroenvironmentCollagencancer diagnosisintraoperative imaginglabel-free imagingnonlinear optical microscopy

Identifiers

PMID35643823
PMCPMC9142840
OpenAlexW4281749592

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.