Evidence map›Paper›PMID 35642081›Full record

ArticleThe clinical respiratory journal2022

Factors affecting abnormal triggering with non-invasive ventilators: A before-and-after study.

Zhaoning Xu, Dongqin Sheng, Kefan Jiao, Chi Zhang, Junping Hao, Dedong Ma

Registry-linked trialOpen access · goldAbstract read
In one paragraph

Article in The clinical respiratory journal, 2022. The graph could read no effect estimate from its abstract, so it casts no vote on the map. It is linked to trial NCT06357780 (Closed-loop syncHronization vErsuS convenTional Synchronization in sPontaneously Breathing Adult Nonivasive Ventilation Patients), which is not on this map. Cited by 1 paper.

0numbers the graph read from it
0cells of the map it votes in
1citing papers in PubMed
0.2field-weighted citation impact, top 52% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

NCT06357780 narecruitingnot on this mapstarted 2024, after this paper: background citation

Closed-loop syncHronization vErsuS convenTional Synchronization in sPontaneously Breathing Adult Nonivasive Ventilation Patients (CHEST-SPAN) - a Randomized Cross-over Trial

TypeinterventionalSponsorBaşakşehir Çam & Sakura City HospitalRan2024 to 2025Enrolled38ConditionsAcute Respiratory Failure, Acute Respiratory Distress Syndrome, Chronic Respiratory FailureArmsclose-loop synchronization controller with spontaneous mode, Conventional
3 · Its place in the literature

Who cites it

1 citing paper in PubMed, 1 citations in OpenAlex.

  1. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

6 authors at 3 institutions in 1 country.

Zhaoning XuSchool of Nursing and Rehabilitation, Shandong University, Jinan, China.ORCID https://orcid.org/0000-0001-9237-2626
Dongqin ShengSchool of Nursing and Rehabilitation, Shandong University, Jinan, China.
Kefan JiaoThe first clinical medical college of Lanzhou University, Lanzhou, China.
Chi ZhangSchool of stomatology, Shandong University, Jinan, China.
Junping HaoDepartment of Pulmonary and Critical Care Medicine, Qilu Hospital, Shandong University, Jinan, China.
Dedong MaDepartment of Pulmonary and Critical Care Medicine, Qilu Hospital, Shandong University, Jinan, China.ORCID https://orcid.org/0000-0002-4269-8254
Shandong University · CNQilu Hospital of Shandong University · CNFirst Hospital of Lanzhou University · CN

Funding

Qilu Hospital of Shandong University 2018-6
6 · The paper itself

Abstract

introductionAbnormal triggering of non-invasive ventilator (NIV) is the main reason for increasing the possibility of patient intolerance and directly affecting the treatment effect.

objectiveTo investigate factors that affect abnormal triggering of NIV.

methodsThirty health volunteers from August 2018 to August 2019 were recruited. Two kinds of NIVs, Curative Flexo ST30 and Resmed Stellar™ 150, were selected, with S/T mode, respiratory rate of 10 bpm and inspiration time of 1.0 s. Every volunteer received ventilation in two ventilators, five oxygen flows (5/10/15/20/25 L/min), five support pressures (independent inspired positive airway pressure/expired positive airway pressure [IPAP/EPAP]: 8/4; 10/4; 12/4; 16/6; 20/8 cm H

resultsAll factors mentioned above affected normal triggering. With the increase of oxygen flow and support pressure, the frequency of auto-triggering and ineffective-triggering increased (P < 0.05). For Curative Flexo ST30 ventilator, when the oxygen injection site was proximal to the ventilator, the frequency of auto-triggering and ineffective-triggering is significantly lower than when it was proximal to the mask, whereas the result in Resmed Stellar™ 150 is totally different (P < 0.05).

conclusionWhen using Curative Flexo ST30 ventilator, the oxygen injection site should be proximal to the ventilator, whereas Resmed Stellar™ 150 ventilator is just the opposite. Attention should be paid to the effectiveness of ventilators when oxygen flow and support pressure settings are high, as abnormal triggers occur more frequently. Choosing the suitable mask is also important.

Indexed as

Noninvasive VentilationVentilators, MechanicalHumansOxygenPositive-Pressure RespirationRespirationRespiratory RateOxygenabnormal triggeringauto-triggeringineffective-triggeringnon-invasive ventilationpatient comfort

Identifiers

PMID35642081
PMCPMC9366579
OpenAlexW4281959678

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.