ArticleAnalytical and bioanalytical chemistry2022
Highly sensitive analysis of low-molecular-mass aldehydes in beverages using a hydroxylamine reagent by high-performance liquid chromatography with fluorescence detection.
Article in Analytical and bioanalytical chemistry, 2022. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
0 citing papers in PubMed.
No citing paper in PubMed yet.
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
13 authors.
Funding
Abstract
In this study, a fluorescent reagent, 4-((aminooxy)methyl)-7-hydroxycoumarin (AOHC), was for the first time applied to label the low-molecular-mass aldehydes (LMMAs) through reductive oxyamination reaction to afford single N,O-substituted oxyamine derivatives at room temperatures with derivatization efficiencies as high as 96.8%. In the following high-performance liquid chromatography with fluorescence detection analysis, 12 LMMAs, including furfurals, aromatic aldehydes, and aliphatic aldehydes, were baseline-separated on an ODS column and detected with low limits of detection (LODs) (0.2-50 nM), and good precisions (intraday relative standard deviations [RSDs] were 2.40-4.68%, and interday RSDs were 4.65-8.91%). This approach was then adopted to analyze six alcoholic beverages and five dairy products, and nine LMMAs with concentrations in the 0.28-798.16 μM range were successfully detected with excellent accuracies (recoveries were 92.2-106.2%). Finally, the results were statistically analyzed and discussed. The proposed method has several advantages, including high sensitivity, room-temperature labeling, and the avoidance of further extraction and/or enrichment procedures, demonstrating its great utility for monitoring LMMAs in various complex matrices.
Indexed as
Identifiers
35641641What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.