Evidence map›Paper›PMID 35637841›Full record

ArticleHardwareX2022

Low cost circulatory pressure acquisition and fluid infusion rate measurement system for clinical research.

Rachel Smith, Amelia Rolfe, Chris Cameron, Geoffrey M Shaw, J Geoffrey Chase, Christopher G Pretty

Abstract read
In one paragraph

Article in HardwareX, 2022. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 3 papers.

0numbers the graph read from it
0cells of the map it votes in
3citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

3 citing papers in PubMed.

  1. Article
  2. Article
  3. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

6 authors.

Rachel SmithDepartment of Mechanical Engineering, University of Canterbury, New Zealand.
Amelia RolfeDepartment of Mechanical Engineering, University of Canterbury, New Zealand.
Chris CameronDepartment of Mechanical Engineering, University of Canterbury, New Zealand.
Geoffrey M ShawDepartment of Mechanical Engineering, University of Canterbury, New Zealand.
J Geoffrey ChaseDepartment of Mechanical Engineering, University of Canterbury, New Zealand.
Christopher G PrettyDepartment of Mechanical Engineering, University of Canterbury, New Zealand.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Acquiring patient physiological waveforms is useful for studying hemodynamic management and developing medical monitoring systems. A low cost, Arduino controlled data acquisition system acquires arterial pressure waveforms (Edwards Lifesciences TruWave compatible) and measures fluid infusion rate using hanging scales. This system can be used at the same time as a clinical monitor, enabling recording of patient arterial pressure and fluid delivery for clinical research. The system is powered via a USB connection, which additionally provides serial output, aiding compatibility and customisation. A simple software user interface, developed in Python, shows outputs. Each data acquisition system, including all necessary connection cables costs ~US$90 and is multiple-use.

Indexed as

Customisable data acquisition systemFluid infusion rateHemodynamic analysisInvasive arterial pressure

Identifiers

PMID35637841
PMCPMC9144005

What OpenQuestion holds

Textmetadata
LicenceCC BY-NC-ND
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.